NEW! IRDye® Goat Anti-Mouse IgM Secondary Antibodies from LI-COR®!

IRDye Dye-labeled Goat anti-Mouse AntibodiesOur IRDye secondary antibody line is growing! We have recently added IRDye Goat anti-Mouse IgM (μ chain specific) secondaries labeled with:

  • IRDye 800CW (PN 926-32280)
  • IRDye 680RD (PN 926-68180) or
  • IRDye 680LT (PN 926-68080).

Just like all of the LI-COR IRDye secondary antibodies, these are highly cross-adsorbed secondary antibody conjugates suitable for a variety of applications (see the table below).

IRDye 800CW secondary antibodies are the antibodies of choice for a wide variety of applications in the 800 nm channel (see the list below). IRDye 800CW secondary antibodies can be used for 2-color detection when multiplexed with IRDye 680RD or IRDye 680LT secondary antibodies.

IRDye 680RD secondary antibodies are the antibodies of choice for In-Cell Western Assay and Western blot applications in the 700 nm channel. These antibodies can be used for 2-color detection when multiplexed with IRDye 800CW secondary antibodies. These antibodies are our most universal use 700 nm channel antibodies. Start using IRDye 680RD first over other 700 nm dyes. Dilution working range 1:10,000 – 1:40,000.

IRDye 680LT secondary antibodies have been proven the brightest signal for Western blot detection in the 700 nm channel and are comparable to Alexa Fluor 680 secondary antibodies. Choose IRDye 680LT secondary antibodies to get high signal and for specific uses of detection in the 700nm channel. These antibodies are not recommended when getting up and running on system. Once established near-infrared protocols are optimized with IRDye 680RD, IRDye 680LT can be used to optimize signals in the 700 channel. Dilution range 1:20,000 – 1:40,000. Note: optimization may be required with IRDye 680LT.

Application IRDye 800CW
Secondaries
IRDye 680RD
Secondaries
IRDye 680LT
Secondaries
Western Blot
In-Cell Western™ Assay Not Recommended
On-Cell Western Assay Not Recommended
Protein Array
Immunohistochemistry
Microscopy
2D Gel Detection
Tissue Section Imaging
Small Animal Imaging Not Recommended
Virus Titration Assay Not Known Not Known
FRET-based Assay Not Known Not Known


Note: Now, as of December 15, 2014, you can also get 0.1 mg sizes of all of our IRDye dye-labeled secondary antibodies. Check out our complete listing here and our new filtering tool!

Studying bone growth, changes, tumors? Try IRDye® BoneTag™ Optical Probes.

BrightSite Optical Imaging Agents
IRDye BoneTag optical imaging agents are tetracycline derivatives that incorporate into mineralizing bone. Structural imaging of bone can be used to more precisely localize an area of disease. A second disease-specific targeting agent with a spectrally-distinct fluorescent label can be used to localize and track disease (such as a tumor) in the same animal. When the two images are overlaid, bone structure is displayed in one color and the other target appears in a different color.

IRDye 680RD BoneTag and IRDye 800CW BoneTag are part of the ready-to-use BrightSite™ optical agents family and make it easy to begin animal studies immediately. These bright fluorescent agents are labeled with IRDye fluorophores for NIR fluorescence optical imaging, and they target a variety of disease characteristics. Simply administer the agent, then image with any small animal imaging equipment with appropriate 680 nm or 800 nm filter sets. No engineered cells or animals are needed.

IRDye BoneTag agent for imaging bone structure and remodeling

Figure 1. IRDye 680 BoneTag agent for imaging of bone structure and remodeling. Tetracycline-derived probe reveals skeletal structure, and signal is stable for weeks. Dorsal view of mouse imaged with IRDye 680 BoneTag. Image acquired with Pearl® Small Animal Imaging System.

We’ll be at AACR in Chicago, April 1 – 4, Booth 3800. Stop by and talk to us about how you can start your small animal in vivo imaging experiments today.

Money-Saving Quick Western Kit Reduces Western Blotting Time by at Least 90 min

Introducing the NEW! Quick Western Kit – IRDye® 680RD

Quick Western Kit - IRDye 680RD

The Quick Western Kit – IRDye® 680RD provides a universal detection reagent that can be combined with the primary antibody incubation step, eliminating the need for a secondary antibody incubation step.

Saves Time (View Workflow)

  • Does not require a separate primary antibody labeling step, saving time and antibody
  • Faster method of detection compared to the traditional 2-step method, which can take up to 4 hours
  • Reduces the total Western blot procedure by at least 90 min

The kit can be used to detect primary antibodies from a variety of hosts and has been shown to recognize primary antibodies to recombinant tagged proteins (i.e. 6X His, Myc, DDK, etc.)

IRDye 680RD Detection Reagent is known to have high specificity for IgG from:

  • Human
  • Mouse
  • Rabbit
  • Guinea Pig
  • Goat
  • Sheep
  • Pig
  • Cow
  • Cat
  • Dog
  • Donkey

The IRDye 680RD Detection Reagent does not work with:

  • Chicken

The Detection Reagent is known to have lower specificity for rat, horse, and hamster. The Detection Reagent has been specifically tested and qualified for Western blot applications. If additional specificity and/or affinity are required, please use IRDye conjugated secondary antibodies for detection.
Quick Western Kit data

Two-fold dilutions of crude lysate containing an overexpressed 6X-His tagged DNA polymerase was loaded in Lanes 3-7. A Histag molecular weight marker (Invitrogen) was loaded in Lanes 1 & 9. The nitrocellulose membrane was blocked with Odyssey Blocking Buffer (PBS) and probed with anti-His Tag Rabbit Polyclonal Antibody (GenScript; 1:500) and IRDye 680RD Detection Reagent (1:1000) for 1 hour. The image was collected on the Odyssey CLx.