Dyes for Your Near-Infrared Imaging Needs

IRDye® 700DX Infrared Dye


The phthalocyanine dye IRDye 700DX has robust properties that make it suitable for optical imaging when conjugated to antibodies, receptor-binding ligands, small molecules, and more. It is considerably less sensitive to photobleaching than many other organic fluorochromes, and has excellent water solubility and salt tolerance.

Features of IRDye 700DX:

  • NHS ester reactive group for labeling primary and secondary amino groups

  • Dye of choice for protein, antibody, or nucleic acid labeling applications where high water solubility is essential

  • Potential as a molecular-targeted cancer therapy, or photoimmunotherapy (PIT)1

  • Excellent photostability, water solubility, and salt tolerance2

  • Alternative to Quantum Dots

1. M. Mitsunaga, M. Ogawa, N. Kosaka, L.T. Rosenblum, P.L. Choyke, H. Kobayashi, Cancer cell-selective in vivo near infrared photoimmunotherapy targeting specific membrane molecules. Nature Medicine17, 1685-1691, 2011.

2. X. Peng, D.R. Draney, W.M. Volcheck, G.R. Bashford, D.T. Lamb, D.L. Grone, Y.Zhang, C.M. Johnson, Phthalocyanine dye as an extremely photostable and highly fluorescent near-infrared labeling reagent. Proceedings of SPIE 6097, 2006.

High Photostability of IRDye® 700DX


Photostability was tested by exposure to many sequential rounds of laser imaging.

  • Remains fluorescent after extended laser exposure

  • More photostable than other 700 nm dyes, including Alexa Fluor 680

Photostability tests of IRDye 700DX showed that IRDye 700DX remains fluorescent after extended laser exposure and is more stable than other 700 nm dyes, including Alexa Fluor 680.

[LEFT] Equimolar amounts of each dye (25 fmol) were spotted onto nitrocellulose membrane. The membrane was scanned repeatedly with the Odyssey Infrared Imaging System, and signal intensity was normalized to maximum intensity at time = 0.


Substantially more photostable than tetramethylrhodamine (TMR), one of the most photostable fluorescent dyes.1

Table 1. Photostability of IRDye 700DX, compared to other near-IR fluorescent dyes, and the very photostable TMR dye

Dye Irradiation intensity I (W/cm2) Intensity Gain factor at surface (Gi) Absorption cross section σ01 (λ) (cm2) Excitation rate constant k01 (λ) (excitation /sec) Measured fluorescence decay rate kz (bleached dye/sec) Mean number of survived excitation cycles µ
IRDye 700DX 24.711 2.823 6.200E-16 (680 nm) 1.479E+05 (680 nm) 0.024 >6.161E+6
Alexa Fluor 680 4.961 2.823 5.355E-16 (680 nm) 2.564E+04 (680 nm) 0.535 4.79E+04
Cy5.5 8.790 2.823 7.270E-16 (680 nm) 6.168E+04 (680 nm) >0.454 1.36E+05
Cy7 27.449 2.823 3.440E-16 (780 nm) 1.045E+05 (780 nm) 0.794 1.317E+05
IRDye 800CW 17.475 2.823 9.180E-16 (780nm) 1.776E+05 (780 nm) 1.730 1.027E+05
TMR 25.073 2.823 2.340E-16 (531 nm) 4.422E+04 (531 nm) 0.191 2.32E+05

1. X. Peng, D.R. Draney, W.M. Volcheck, G.R. Bashford, D.T. Lamb, D.L. Grone, Y.Zhang, C.M. Johnson, Phthalocyanine dye as an extremely photostable and highly fluorescent near-infrared labeling reagent., Proceedings of SPIE 6097, 2006.

IRDye® 700DX Products


 

Visit us on You TubeLike us on Facebook!Follow us on TwitterRed the blogger blog

Biotechnology
4647 Superior St Lincoln, NE 68504
Toll-Free: 800-645-4267
Email: biohelp@licor.com
Environmental
4421 Superior Street Lincoln, NE 68504
Toll-Free: 800-447-3576
Email: envsales@licor.com
© 2011 LI-COR Biosciences