Image Studio Software
Image Studio is an extremely simple and easy-to-use imaging software. It is compatible with the Odyssey® CLx, Odyssey Classic, and Odyssey Fc Imaging Systems.
- Easy to use - Training for new users is fast and simple
- Intuitive, application-driven ribbon interface
- Compatible with PC and Mac® computers
Unique to the Odyssey CLx is a new AutoScan function that eliminates the guesswork of finding the correct intensity and the need for re-imaging data. This results in a wide dynamic range of greater than six logs, with minimized saturation. The AutoScan function makes it easy for even new users to efficiently acquire high quality data.
Image Studio supports nine different types of analyses when used with the Odyssey CLX, including Western blots, DNA gel documentation, and small animal imaging.
Figure 1. Image Studio imaging software features an intuitive, application-driven ribbon interface. Each instrument has its own unique ribbon that displays analysis and formatting tools for user selection and implementation. The above ribbon is Image Studio for the Odyssey CLx Infrared Imaging System.
Image Studio 2.0 Features and Benefits Video
Image Studio Quick Start Card for the Odyssey CLx and Odyssey Classic
One-Button Image Acquisition
Image Studio software is the key to fast, easy image acquisition and analysis with the Odyssey CLx, Odyssey Classic, or Odyssey Fc Imager. Push a button, and the blot is imaged in the detection channels you choose.
Instructions on how to install Image Studio Software.
How to Adjust the Lookup Tables in Image Studio
for an Optimal Image Display

[Above] Dedicated Western Analysis and MPX™ Western ribbons offer tools for quick placement of lane and band markers on the image to speed up data analysis.
[Left] Use sliders to adjust the appearance of the image on the screen. Lock the settings across multiple images for accurate comparison. analysis.
Minimum Computer Specifications for Image Studio Compatibility:
- Mac: 2 GB RAM; OS 10.6 or 10.7 (Snow Leopard or Lion);
- PC: 4 GB RAM; Win7, XP, or Vista;
- Odyssey software minimum requirements: Embedded Software: Classic: 2.1.15 or higher; CLx: 1.0.9 or higher; Fc: 1.0.14 or higher
[Above] Now you can easily create electronic or hard-copy lab reports customized to meet your specific needs. Design customized templates in Image Studio using a drag-and-drop approach to arrange the content. Then, simply select the desired template to format your data for a custom report.
You can easily design multiple templates and prepare various reports based on your intended audience. If your record-keeping method must vary to meet different documentation requirements (such as GLP or ISO), you can quickly re-arrange a report or add information while maintaining your original Lab Book Report.