FieldBrite™ XT Technology Dual-Mode Western Imaging At Its Best
The laser-based system in Odyssey® Fc combines with FieldBrite XT technology to acquire images with uniform field illumination without saturated pixels. This innovative, patented technology yields very low total noise and can deliver up to 6 logs of dynamic range for superior sensitivity and imaging quality for both detection methods.
Simply the Best Signal-to-Noise Ratios
FieldBrite XT technology features a patented filtering system that delivers low total noise for acquisition times of up to one hour.
- Get optimized signal-to-noise ratio as image acquisition progresses to ensure superior image quality and level of detection.
- No need to bin as this advanced laser-based detection platform delivers high sensitivity without the need to manipulate data by binning, which can compromise image resolution and ability to quantitate.
Wide Dynamic Range
With its wider dynamic range, the Odyssey Fc Imager accurately captures both strong and weak signals in the same image.
- Up to 6 logs of dynamic range for superior sensitivity and imaging quality for both chemiluminescence and infrared fluorescence detection.
- Detect low and high protein concentrations.
- Get the complete protein concentration range in a single image without signal saturation.
No Supercooling Needed
Traditional CCD imagers typically supercool the camera in an effort to reduce noise and improve image quality. Supercooling requires additional energy consumption to maintain operational efficiency and causes longer wait times when powering up the camera.
- Obtain reduced total noise without the need to supercool the camera.
- Maintain operational efficiency and save energy.
Two Methods, One System
The Odyssey Fc System is the ideal solution for researchers who depend on both detection methods to achieve their research goals. Now you can combine both methods in a single imager saving time, lab space, and valuable research dollars.
- With the Odyssey Fc System, chemiluminescent imaging is streamlined for excellent results with minimal user adjustments and no multiple exposures.
- With the proven accuracy and linearity of the Odyssey Fc System and infrared fluorescent imaging, you can be confident of the differences you see in protein levels.

[Above] Laser module contains a 685 nm laser and a 785 nm laser. FieldBrite XT technology ensures uniform illumination of the sample, low coefficient of variation (%CV), and exceptional reproducibility. Illustration depicts activation of 685 nm channel.