Introducing the

LI-6400XT

Portable Photosynthesis System

NEW - Supports Compact Flash Memory
NEW - Ethernet Connectivity
NEW - Faster 400 MHz Processor
NEW - Bar Code Reader Support
NEW - OPEN Version 6 Software

Learn about the new LI-6400XT

What's New

LI-6400XTA Whole Plant Arabidopsis
Gas Exchange System

The LI-6400XTA is designed for molecular biologists, plant physiologists, and geneticists who are interested in studying whole plant respiration.
Go there More

Whole Plant Arabidopsis Chamber
and RGB Light Source
LI-COR introduces two new accessories for the LI-6400XT - a chamber for whole plant Arabidopsis studies, and a Red/Green/Blue (RGB) light source that can be attached to the chamber.
Go there 6400-17 Whole Plant Arabidopsis Chamber
Go there 6400-18 RGB Light Source

6400-926 XT Upgrade Kit now available for LI-6400 instruments
Featuring a new digital board, OPEN version 6 software, support for Multiphase Flash (MPF) Protocol, and additional upgrades.
Go there More

Bar Code Reader Capability
OPEN 6 provides functionality for connection of an RS-232 compatible bar code reader to the LI-6400/XT.
Go there More

Expanded Temperature Control Kit
A new accessory for the LI-6400/XT allows you to increase the range of temperature control of the LI-6400/XT sensor head block.
Go there More

Multi-Level Flash Option
(for the 6400-40 Leaf Chamber Fluorometer)
With Version 5.3 and above OPEN software, the LI-6400/6400-40 System supports two types of saturating flashes; single or multiple intensity.
Go there More

Leg Extensions
Give your knees a break, and raise the LI-6400/XT an additional 12” with these screw-on leg extensions.
Go there More

LI-COR is pleased to announce another significant step forward with the LI-6400 System – the new LI-6400XT. Rather than rest on the LI-6400’s considerable accomplishments as the undisputed market leader, LI-COR continues to innovate and enhance on a proven, familiar platform. The first new feature you’ll notice with the LI-6400XT is a small access panel that covers an expansion slot; this slot supports compact flash memory cards, or an Ethernet connector. What you may not notice is the new, faster computer inside, in the form of a 400 MHz processor on the new digital board… or the new OPEN version 6 software that runs the instrument. Click on the tabs below to learn more about enhanced XT features.

CF Card

Take advantage of the convenience that removable flash memory provides:

  • Archive your files.

  • Transfer files from the field to the laboratory or office, or vice versa, without moving the instrument.

  • Transfer files to other LI-6400XTs.

  • Forget the cables completely – just pop the card out and view or chart your data files on your computer.

Ethernet Adapter

Include the LI-6400XT in your LAN

Just plug it in – your LI-6400XT will appear with a unique name (based on your unit’s serial number). No additional software is required. Now you can…

  1. Drag and drop files between instruments, computers, or even printers.

  2. Configure multiple LI-6400XTs in the same way, by moving configuration files.

  3. Skip the file transfer completely, and simply open an LI-6400XT data file with your favorite spreadsheet or statistical analysis package.

LI-6400 LAN

Upgrade Your Current LI-6400   -   6400-926 XT Upgrade Kit now available

LI-COR understands that purchasing an LI-6400 is a substantial investment, worthy of careful consideration. Knowing this, we have created a solid platform upon which we can continue to develop and improve, utilizing the latest technological advances. This is why even the earliest LI-6400s are still being used today, rather than sitting idle on a shelf; the LI-6400 was an excellent investment then, and will continue to be in the future.

So, if you’re wondering if your current LI-6400 can be upgraded to an LI-6400XT, the answer is yes. LI-COR can provide an upgrade package (part number 6400-926) that consists of a new 400 MHz digital board, and a new instrument case that provides an access door for the compact flash/Ethernet expansion slot. OPEN 6 software, revised instruction manuals, a compact flash memory card, Ethernet card adapter, and Ethernet cable are included, as well. The upgrade kit can be user installed, or the instrument can be returned to LI-COR or a LI-COR distributor for installation.

Processor History Table

If you’re not interested in upgrading to the faster digital board and expansion slot, you can still take advantage of OPEN 6’s new features (minus the Ethernet and memory card capabilities, of course); and as always, software upgrades will continue to be free for the life of the instrument. NOTE: OPEN 6 requires 200 MHz digital board or above.

Training & Support

  • Hands-on training classes, worldwide service and support

  • Distributors for over 40 countries

  • L-Term software enables remote support and instrument diagnosis via the internet

  • Expertise of LI-COR application scientists and support staff available daily by phone or e-mail

  • New! LI-6400 Training CD set

 
 