LI-COR's chambers are carefully constructed for ultimate ease of use and minimal environmental disturbance. Internal surfaces are nickel plated to minimize water sorption, and external surfaces are either bright anodized aluminum or covered with titanium dioxide white epoxy to minimize radiation absorptance and maximize emissivity. The chamber gaskets have minimal interaction with CO2 and water vapor, seal tightly, and do not exhibit a permanent memory where leaf midribs and other structures press into the gaskets when the chamber is sealed. In the 6400-05, -07, -08, and -15 leaf chambers, the leaf temperature is estimated from energy balance. In all other chambers, leaf temperature is measured using a leaf temperature thermocouple. |
![]() |
6400-02B LED Light SourceThis Red/Blue Light Source not only provides red actinic light source to drive photosynthesis, but also provides a blue component to control stomata. Red LED's are used to provide radiant output at 665 nm (nominal), while blue LED's provide output at 470 nm. The output of the blue LED's is crucial for studying stomatal kinetics (Zeiger, et al., 1987). For more information click here. Download 6400_02B Brochure |
![]() |
6400-05 Conifer ChamberThe conifer chamber is constructed of acrylic for durability and lined with teflon to minimize water sorption. Shoots with needles up to 3.5 cm long can be accommodated in the 7.5 cm diameter chamber. The 6400-05 mounts directly to the sample cell of the system's CO2 and H2O IRGAs. Download
6400-05 Chamber Brochure |
![]() |
6400-07 Needle ChamberPhotosynthesis rates of long needled conifers are easily measured using the 6400-07 Needle Chamber. The 6400-07 has a 2 x 6 cm aperture and specially designed foam mounting pads that hold up to five needles in the chamber. The 6400-07 allows each needle to be pressed into place in the chamber, where it is held securely in the channels of the foam mounting pad. The chamber top and bottom have replaceable clear Propafilm® windows for excellent light transmittance. A quantum sensor in the chamber provides light measurement at the plane of the needles. Download
6400-07 Chamber Brochure |
![]() |
6400-08 Clear Chamber BottomIlluminating the bottom of a leaf is particularly useful for survey measurements and erect foliage. The Clear Chamber Bottom has a Propafilm® window similar to the standard chamber top. The Clear Chamber Bottom is designed to be used with any 2 x 3 cm chamber top. Download
6400-08 Chamber Brochure |
![]() |
6400-09 Soil CO2 Flux ChamberFor soil CO2 flux measurements using the LI-6400/6400XT. For more information click here. Download 6400-09
Chamber Brochure Measurements
of Soil CO2 Flux (poster reprint) |
![]() |
6400-11 Narrow Leaf ChamberThe 6400-11 Narrow Leaf Chamber is ideal for foliage with narrow-bladed leaves. The 6400-11 has a 2 × 6 cm aperture like the 6400-07 Needle Chamber and uses the same chamber top. A PAR sensor for light measurement at the leaf plane is included. Download 6400-11
Chamber Brochure |
![]() |
6400-15 Extended Reach 1 cm ChamberThe 6400-15 Extended Reach 1 cm Chamber was designed for measurement of small
leaves such as Arabidopsis, which are difficult to clamp with conventional
chambers. Download 6400-15
Extended Reach 1 cm Chamber Brochure |
![]() |
6400-19 Custom Chamber KitContains the sample optical path mounting plate and accessories commonly used to make custom chambers for the LI-6400/6400XT, like the one shown at left. Download 6400-19
Chamber Brochure |
![]() |
6400-40 Leaf Chamber FluorometerThe 6400-40 Leaf Chamber Fluorometer transforms the LI-6400/6400XT System into the most integrated and powerful Portable Fluorescence and Gas Exchange System available. Stressed Plants? A new LI-COR publication illustrates why the 6400-40 Leaf Chamber Fluorometer is an ideal complement to expand the analysis capabilities of the LI-6400/6400XT System Click here to see why or view the Integrated Fluorescence area of our website. |
Fluorescence Adapter ChambersAdapters to accommodate fiber probe sizes of 2 mm (6400-10), 8
mm (6400-06), and 10 mm (6400-14) are available. Each chamber has
a quantum sensor that allows incident irradiance to be measured. |
|
Accessories |
|
|
6400-89 Insect Respiration KitThe 6400-89 Insect Respiration Kit is available to those LI-6400/6400XT users interested in measuring the respiration rate of insects, small mammals, small fruits, nuts, etc. The kit contains a desiccant tube/chamber into which the sample(s) is placed, and a Sample Cell Outlet Manifold Kit (p/n 9964-053) that isolates the LI-6400/6400XT sample cell from the leaf chamber so that the instrument can be used as a stand-alone gas analyzer. 6400-89 Insect Respiration Kit |
|
6400-88 Expanded Temperature Control KitThe 6400-88 Expanded Temperature Control Kit is a new accessory for the LI-6400/6400XT Portable Photosynthesis System that is used to increase the range of temperature control of the system sensor head block.
6400-88 Expanded Temperature Control Kit |
|
6400-70 AC ModuleThe new 6400-70 AC Module allows the LI-6400 to be powered from mains power. It consists of a transformer and a separate battery-shaped unit that fits in the LI-6400/6400XT console. When used with a battery, the 6400-70 will trickle charge the battery, which also provides for continued operation in the event of a mains power failure. Download 6400-70 AC Module Brochure |
|
Dark Adapting ClipsA new accessory for the 6400-40 Leaf Chamber Fluorometer that allows you to dark-adapt leaf samples is now available. Each Dark Adapting Clip consists of two "shutters", and a clip that secures the shutters over the leaf. The Dark Adapting Clip (with the shutters in the closed position) is attached to the leaf; after the leaf is fully dark-adapted, the Clip is secured to the Leaf Chamber Fluorometer, the shutters are opened, and the measurement is taken. A kit including 10 clips and 10 sets of shutters is available under part number 9964-091. Download Dark
Adapting Clip Brochure |
|
Upgrade your LI-6400 with the 6400-926 XT Upgrade KitThe 6400-926 Upgrade Kit converts your LI-6400 to an LI-6400XT. The kit can be user installed, or the instrument can be returned to LI-COR or a LI-COR distributor for installation. What does the Upgrade Kit include?
Learn more about the LI-6400XT, click here. NEW! Save money by taking advantage of the new 6400-40DBX value package, which includes the 6400-40 Leaf Chamber Fluorometer (with spares kit and instruction manual) and the 6400-926 XT Upgrade Kit with OPEN version 6 software. To learn more about the 6400-926 XT Upgrade Kit, click here, or contact LI-COR or your LI-COR distributor for more details.
|
|
9964-053 Sample Cell Outlet ManifoldThe 9964-053 Sample Cell Outlet Manifold replaces the standard LI-6400 bottom chamber. The manifold's purpose is to isolate the gas analyzer sample cell from the leaf chamber so the LI-6400/6400XT can be used as a stand-alone gas analyzer. Download 9964-053 Sample
Cell
Outlet Manifold Brochure |
![]() |
9964-098 Leg Extension SetGive your knees a break, and raise the LI-6400/6400XT an additional 12" with these screw-on leg extensions. |