6400-17 Whole Plant
Arabidoposis Chamber

• Whole Plant Measurements
• Uses 2.5 in. pots or 1.5 in. Cone-tainers
• O-ring Seal

Arabidopsis Brochure DownloadGo there Download Brochure .

Go there Watch this video to learn more about the Whole Plant Arabidopsis Chamber and
RGB Light Source

6400-17L Package

Combine the 6400-17 and 6400-18 RGB Light Source

RGB Source MountedCombine the 6400-17 Whole Plant Arabidopsis Chamber and the 6400-18 RGB Light Source in a complete package (6400-17L) for your whole-plant Arabidopsis studies. The package includes an external power supply for the 6400-18 Light Source (100-240V, 1.5A, 50-60 Hz) that can be mounted to the LI-6400/6400XT console (below). OPEN 6.1 (or above) software is required, which contains a dedicated configuration for the 6400-18 RGB Light Source. NOTE: OPEN 6.1 (or above) can be installed on 200 MHz (ver 5.x) or 400 MHz (ver 6.x) digital boards. Older boards require a digital board upgrade - contact LI-COR for details.

Ordering Information

6400-17 Whole Plant Arabidopsis Chamber

Includes chamber bottoms for 1.5 in. Cone-tainer™ and 2.5 in. pot, spare parts kit, exhaust tubes, 1.5 in. Cone-tainers, 2.5 in. pots, and installation instructions.

6400-17L Lighted Whole Plant Arabidopsis Chamber

Includes 6400-17 Whole Plant Arabidopsis Chamber and 6400-18 RBG Light Source at a package price.

The 6400-17 Whole Plant Arabidopsis Chamber is the newest addition to the family of chamber accessories for the LI-6400/ 6400XT Portable Photosynthesis System. The large diameter (2.75 in., 7 cm) of the 6400-17 allows for measurements of entire Arabidopsis rosettes, rather than just the leaves. Measuring whole rosettes allows for repeatable measurements for growth studies that were previously difficult to achieve without the use of custom chamber configurations.

The 6400-17 is easily integrated with the LI-6400/6400XT sensor head by mounting to the lower leaf chamber manifold. Because the 6400-17 mounts directly to the lower manifold, excellent air mixing is achieved without the need for additional fans within the chamber.

2.5" PotInterchangeable chamber bottom plates are provided for use with readily available 2.5 in. (65 mm) pots or 1.5 in. (38 mm) Cone-tainers. Chamber air temperature is measured by a thermocouple in the air return path, preventing radiant effects from the light source. This thermocouple plugs into the existing thermocouple block on the LI-6400/ 6400XT sensor head. The leaf temperature is computed in software using an energy balance approximation. An o-ring sealed top plate with a Propafilm covering is placed over the chamber when making measurements. The o-ring provides a tight seal that eliminates the need for traditional foam gaskets.

Because soils or artificial media are present within the chamber volume, CO2 fluxes from the soil can be introduced into the whole plant measurement. A standard peat media mix capped with a heavy clay layer on top suppresses soil respiration. An exhaust tube fitting is also provided that can be used to apply a slight over-pressure within the chamber, which also suppresses CO2 fluxes from the soil.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 


Biotechnology
4647 Superior St Lincoln, NE 68504
Toll-Free: 800-645-4267
Email: biohelp@licor.com
Environmental
4421 Superior Street Lincoln, NE 68504
Toll-Free: 800-447-3576
Email: envsales@licor.com
© 2009 LI-COR Biosciences