LI-8100TR Automated Soil CO2 Flux and Atmospheric Monitoring System - Teaching & Research Package

LI-6400XT and Students

Available in the United States, Puerto Rico, and Canada

Why the LI-8100TR Package

The college classroom and field laboratory provide the bridge for today's students to become tomorrow's researchers. The rapidly accelerating study of environmental climate change offers a new generation of scientists unprecedented challenges and opportunities. In order to be properly trained, students need to gain experience in CO2 measurement theory, practical application, and instrumentation. The LI-8100TR provides educators and researchers sophisticated CO2 monitoring instrumentation in a dedicated system that is integrated and easy to use. It accurately measures soil CO2 flux as well as vertical atmospheric CO2 profiles. The LI-8100TR is the complete teaching and research package at a great savings.

Benefits for Teaching

The LI-8100TR is a perfect fit for educational and research based instruction, offering complete instrumentation for a variety of applications. The LI-8100TR includes a field guide on CD with prepared field exercises, and includes instrumentation for educators to quickly implement a variety of systems for incorporation into their curricula.

  1. Soil CO2 Flux Measurements - Spatial or Temporal Measurements or both
    • Survey measurements - spatial variability of soil CO2 flux. Cover a large area in a short period of time
    • Long-term, single chamber measurements - temporal variability of soil CO2 flux
    • Multiplexed, four chamber measurements - spatial and temporal variability of soil CO2 flux
    • Measure soil temperature and moisture with included sensors
    • Measure other parameters, such as wind speed and direction (use-supplied sensors)
  2. Vertical atmospheric profile CO2 studies as well as horizontal atmospheric CO2 measurements
    • Profiling kit is included
    • Measure up to four different heights
    • Measure along four horizontal locations
    • No additional cost
  3. Sample chamber air for analysis of additional trace gases flux across the soil surface (i.e. CH4, N2O etc)
    • Trace gas sampling kit is included
    • Further analysis is required using chromatography or other analytical methods
Product Model Number Included Product Name Notes
LI-8100 1 Analyzer Control Unit The gas analysis, communications center, data storage center, and power center. Can also connect auxiliary sensors directly.
LI-8150-8 1 Multiplexer, 8-port Connect up to 8 long-term chambers and/or use it for atmospheric profiling.
8100-103 1 Survey Chamber, 20 cm Connect directly to the LI-8100 for fast and repeatable survey measurements.
8100-104 4 Long-Term Chamber Connect directly to the LI-8100 for single chamber long-term measurements or connect to the LI-8150-8 to multiplex.
8150-705 4 Cable/Hose Assembly, 15 m For connecting the 8100-104 to the LI-8150-8.
8150-704 1 Cable/Hose Assembly, 2 m For connecting the 8100-104 to the LI-8100 for single chamber, long-term measurements.
8150-770 1 AC Power Supply For use with the LI-8150-8 in order to multiplex.
8150-706 1 DC Power Cable For connecting a user-supplied battery with the LI-8150-8 in order to multiplex.
8100-202 1 Soil Moisture Probe For use with the LI-8100 and 8100-103 for survey measurements or 8100-104 for single chamber, long-term measurements.
8100-201 1 Soil Temperature Probe For use with the LI-8100 and 8100-103 for survey measurements only.
8100-203 1 Soil Temperature Thermistor For use with the LI-8100 and 8100-104 for single chamber, long-term measurements.
8150-202 4 Soil Moisture Probe Connects directly to the 8100-104; for use only if you multiplex.
8150-203 4 Soil Temperature Thermistor Connects directly to the 8100-104; for use only if you multiplex.
8150-662 1 Profiling Kit Connects to the LI-8150-08 (includes 4 ports).
8100-664 1 Trace Gas Sampling Kit Sample the same air stream used for CO2 flux for further trace gas analysis.
8150-250 5 Bev-a-line For use with the Profiling kit (250 ft total).
8100-561 1 Wireless Communications Package For use with any possible system configuration.
6400-03 3 Battery Used for the LI-8100 and 8100-103 only.
LI-6020 1 Battery Charger Used to charge the 6400-03 batteries.
8100-785 1 Two-Year Extended Warranty Extends the standard one-year warranty for the LI-8100 to a total of three years.
8150-785 1 Two-Year Extended Warranty Extends the standard one-year warranty for the LI-8150-8 to a total of three years.
8100-520 1 Field Guide A CD containing field exercises used for teaching or research.

A number of upgrades are available as future teaching and research needs change.

  1. Upgrade the 8 port Multiplexer (LI-8150-8) to a 16 port Multiplexer (LI-8150-16)
  2. Add more long-term chambers and accessories as needed
  3. Add the 8100-102 (10cm diameter) survey chamber
  4. If upgrades and/or additional chambers or any accessories are purchased with this package on the same order, a 10% discount will apply to the entire additional items purchased.

LI-8100TR Package Pricing & Questions

For pricing information or if you have any questions or you need a quote please contact Chris Mantzios, National Sales Manager at 800-447-3574 ext 3754, chris.mantzios@licor.com or Kristin Feese, Technical Sales Associate at 800-447-3576 ext 3882, kristin.feese@licor.com.

 


Biotechnology
4647 Superior St Lincoln, NE 68504
Toll-Free: 800-645-4267
Email: biohelp@licor.com
Environmental
4421 Superior Street Lincoln, NE 68504
Toll-Free: 800-447-3576
Email: envsales@licor.com
© 2009 LI-COR Biosciences