Light Measurement Ordering Information
Terrestrial Sensors
LI-190 Quantum Sensors
LI-190SA Quantum Sensor (with BNC connector)
LI-190SZ Quantum Sensor (with bare leads)
LI-190SL Quantum Sensor (with standardized millivolt adapter)
LI-190SA-50 Quantum Sensor (50 ft lead with BNC connector)
LI-190SZ-50 Quantum Sensor (50 ft lead with bare leads)
LI-190SL-50 Quantum Sensor (50 ft lead with standardized millivolt adapter)
LI-191 Line Quantum Sensor
One meter in length, includes 3 m (10 ft) cable, bubble level, and carrying case. Continuous photodiode rod averages signal over entire meter length.
LI-191SA Line Quantum Sensor (with BNC connector)
LI-191SL Line Quantum Sensor (with standardized millivolt adapter)
LI-200 Pyranometer
LI-200SA Pyranometer (with BNC connector)
LI-200SZ Pyranometer (with bare leads)
LI-200SL Pyranometer (with standardized millivolt adapter)
LI-200SA-50 Pyranometer (50 ft lead with BNC connector)
LI-200SZ-50 Pyranometer (50 ft lead with bare leads)
LI-200SL-50 Pyranometer (50 ft lead with standardized millivolt adapter)
LI-210 Photometric Sensors
LI-210SA Photometric Sensor (with BNC connector)
LI-210SL Photometric Sensor (with standardized millivolt adapter)
Terrestrial Accessories
LI-COR Recommends: 2003S Mounting and Leveling Fixture for use with LI-190, LI-200, and LI-210 Sensors. Allows user to mount sensor and ensures sensor is level while taking measurements.
2222SB-50 Extension Cable (50 ft) for use with "SA" or "SL" sensors.
2222SB-100 Extension Cable
(100 ft) for use with "SA" or "SL" sensors.
2200 Adapter Converts "SA" type sensors (with BNC connectors) to "SZ" type
(bare wires).
2290 Millivolt Adapter For use with LI-190SA, LI-191SA, or LI-210SA sensors.
2220 Millivolt Adapter For use with LI-200SA sensors.
LI-250A Light Meter
Includes one BNC connector for direct connection of "SA" version light sensor. Displays data on easy-to-read screen. Press HOLD to pause the readings, or AVERAGE for a 10-second average. Does not store data. Includes battery and instruction manual.
LI-250A Light Meter Accessory
250-01 Carrying Case
Underwater Sensors
LI-192SA Underwater Quantum Sensor
LI-193SA Spherical Underwater Quantum Sensor
The LI-192SA and LI-193SA must be used in combination with a 2222UWB Underwater Cable. This combination can be directly connected to the LI-250A Light Meter or LI-1400 Data Logger. The 2291 Millivolt Adapter should be ordered if the LI-192SA will be used with a data acquisition device or data logger that measures millivolts.
Underwater Accessories
2222UWB-3 Underwater Cable
3 meters
2222UWB-10 Underwater Cable
10 meters
2222UWB-30 Underwater Cable
30 meters
2222UWB-50 Underwater Cable
50 meters
2222UWB-100 Underwater Cable
100 meters
LI-COR Recommends: 2009S Lowering Frame. Provides stability and orientation for one or two underwater sensors.
100L Lubricant Lubricates and displaces water in underwater connectors.
2291 Millivolt Adapter For use with either the LI-192SA or LI-193SA.
2290 Adapter Converts "SA" type sensors (with BNC connectors) to "SZ" type
(bare wires).
LI-1400 Datalogger
Designed for easy connection to LI-COR light sensors. Includes three BNC connectors for use with "SA" version light sensors. Additional sensors ("SZ" version) can be connected via the 1400-301 Terminal Block (sold separately). Includes 4 AA batteries, RS-232 Serial Cable, RS-232 to USB Adapter, Windows Communication Software and Instruction Manual. Sensors sold separately.
LI-1400 Datalogger Accessories
1400-301 Standard Terminal Block
1400-320 Storage Case
1400-401 AC Power Supply
(110V only) *
1400-402 External Alkaline Battery Pack *
Requires 6 D Cell batteries (not included).
1400-101 Air Temperature Sensor with 6 m (20 ft) cable *
1400-102 Air Temperature Sensor with 0.6m (2 ft) cable *
1400-103 Soil Temperature Sensor with 6 m (20 ft) cable *
1400-104 Relative Humidity/Air Temperature Sensor (Viasala) *
Includes 2.75 m (9 ft) cable.
* Requries 1400-301 Standard Terminal Block in order to connect to LI-1400 Datalogger.