WesternSure ECL Stripping Buffer for Chemiluminescent Westerns
Chat With Us

WesternSure® ECL Stripping Buffer

Product Ordering Information

Order online or contact your local sales office.

Order online or contact your local sales office.

Order online or contact your local sales office.

To order, please contact your local distributor

  • Robust formulation removes primary and secondary antibodies from PVDF or nitrocellulose membranes
  • Maintains target antigen integrity for efficient reprobing
  • Does not require hazardous shipping, unlike many other stripping buffers

WesternSure ECL Stripping Buffer is ideal for stripping and reprobing chemiluminescent Western blots.

WesternSure ECL Stripping Buffer is not recommended for loading amounts over 30 µg. It will demonstrate decreased performance when used at 2X or 5X concentration and heating the solution will not increase the stripping efficiency.

WesternSure ECL Stripping Buffer is effective for reprobing with different antibodies

Figure 1. WesternSure ECL Stripping Buffer is effective for reprobing with different antibodies. Original: EGF-stimulated A431 lysate (10 and 5 µg total protein) was probed with mouse anti-ERK2 followed by detection with WesternSure HRP Goat anti-Mouse (LI-COR P/N 926-80010) and WesternSure PREMIUM Chemiluminescent Substrate (LI-COR P/N 926-95000). The blot was exposed to film for 20 sec. Stripped: The blot was then stripped with WesternSure ECL Stripping Buffer (LI-COR P/N 926-92000), followed by detection with WesternSure PREMIUM, and exposed to film for 10 min. Reprobed: The blot was re-blocked and reprobed with Beta-Actin Monoclonal (LI-COR P/N 926-42212) followed by detection with HRP Goat anti-Mouse and WesternSure PREMIUM. The blot was exposed to film for 20 sec.

 WesternSure ECL Stripping Buffer is effective for antibody optimization experiments

Figure 2. WesternSure ECL Stripping Buffer is effective for antibody optimization experiments. Human transferrin (400 ng to 12.5 ng/lane) was probed with rabbit anti-transferrin (1:1000) followed by detection with HRP conjugated Goat anti-Rabbit IgG (LI-COR P/N 926-80011) and WesternSure PREMIUM Chemiluminescent Substrate (LI-COR 926-95000). Chemiluminescence was detected with Odyssey® Fc Imaging System using a 2 minute acquisition (Original). The blot was then stripped using WesternSure ECL Stripping Buffer (LI-COR P/N 926-92000) and imaged on Odyssey Fc. (Stripped) The blot was reprobed with different concentrations of the same primary and secondary antibodies (1:5,000 and 1:50,000 respectively) followed by detection with WesternSure PREMIUM. The blot was imaged on Odyssey Fc using a 2 minute acquisition (Reprobed. All images are linked to the original image for comparison using Image Studio™ software.