The LEEF Carbon Monitoring System Includes:

Exclusive Grant LI-COR offers the LEEF Carbon Monitoring System with a grant covering 50% of the list price for qualified LEEF participants

Field Measurement
Grant
Information

How to Apply
Apply now
For more information about the LEEF Program, contact us:

LI-8100A Analyzer Control Unit:

  • The gas analysis, data storage and communication center of the LI-8100A System.

Eight-Port Multiplexer:

  • Allows for connection of up to eight long-term chambers (four long-term chambers are included in the LEEF Carbon Monitoring System) for soil CO2 flux and/or use available ports for other applications.

Chambers

  • Survey Chamber, 10 cm: Connects directly to the Analyzer Control Unit. Includes Soil Temperature Probe, gasket kit, spares kit, and six soil collars
  • Survey Chamber, 20 cm: Connects directly to the Analyzer Control Unit. Includes Soil Temperature Probe, gasket kit, spares kit, and six soil collars
  • Four Long-term Chambers, 20 cm: Designed for use with the Multiplexer. Can also be used with the Analyzer Control Unit. Includes gasket kit, spares kit, and two soil collars
  • Clear Chamber Bowl Assembly: Used to convert one long-term chamber to a clear chamber for Net Carbon Exchange studies

Specialized Sampling Kits

  • Flask Sampling Kit: Includes all hardware needed to connect up to eight flasks to the Multiplexer
  • Trace Gas Sampling Kit: Used to collect samples from the same air stream used to measure CO2 flux for further trace gas analysis
  • Profiling Kit: Used for both vertical or horizontal profile measurements

Additional Sensors and Probes

  • Quantum Sensor and Amplifier: Used for Net Carbon Exchange studies
  • Theta Soil Moisture Probe: with bare leads for direct connection to the Analyzer Control Unit
  • Four Soil Moisture Probes: Used for multiple chamber measurements
  • Four Soil Temperature Thermistors: Used for multiple chamber measurements

Additional Package Components

  • Four Cable/Hose Extension Assemblies, 15 m: Used to connect long-term chambers to the multiplexer
  • Cable/Hose Assembly, 2 m: Used to connect a single long-term chamber to the Analyzer Control Unit
  • AC Power Supply: Used to power multiple long-term chambers with mains power
  • 8100-iOS-in-field
  • DC Power Cable: Used to connect the system to a user-supplied battery
  • Five Bev-A-Line packages: Used for profiling studies along with the profiling kit
  • Leveling Stake: Used with the Quantum Sensor for Net Carbon Exchange studies
  • CO2 Mapping Kit: Used to measure and map carbon dioxide emissions over a large area
  • 8100App Wireless Package: Includes 32 GB iPod, iPod Micro Case, Cisco® Wireless (802.11b) Card, and serial cable for IP configuration
  • Three Rechargeable Batteries and a Battery Charger: Used for survey measurements. One battery needed to operate the LI-8100A. Each battery provides approximately 3 hours of battery life
  • Windows® and Apple iOS interface Software, Mapping software, and Data Analysis software
  • $500 Consumables Voucher: Used to purchase any consumable you may need over a five year period
  • $500 Travel Voucher: For presentation of qualifying undergraduate research

Service and Training

  • Four-Year Extended Warranty: Extends the standard one-year warranty of the LI-8100A, Multiplexer, and all six chambers to a total of five years
  • Four certificates for three-day training course held at LI-COR Biosciences
  • Five sets of Training DVDs: A two-DVD set each. Great for new users of the LI-8100A
  • LI-8100A Teaching Resource DVD/CD Set
  • Full Scientific and Technical Support

The LEEF Carbon Monitoring System is designed for multiple applications and offers the flexibility for students to perform undergraduate research in as many as 10 different topics or to be used by faculty in a diverse curriculum.