The LI-8100TR Package

The LI-8100TR is the most complete package LI-COR offers and includes all hardware needed for survey, single-chamber long-term or four-chamber multiplexed measurements. In addition, you can perform atmospheric measurements as well as sample for further trace gas analysis.

Package includes:

As your teaching and research needs grow, so can the LI-8100A system. Its modular design allows for additional chambers to be added at any time.

  • LI-8100A Analyzer Control Unit
    • The gas analysis, communications center, data storage center, and power center. Can also connect auxiliary sensors directly.
  • LI-8150-8 Multiplexer, 8-port
    • Connect up to 8 long-term chambers and/or use it for atmospheric profiling.
  • 8100-103 Survey Chamber, 20 cm
    • Connect directly to the LI-8100A for fast and repeatable survey measurements. Includes six collars.
  • 4 8100-104 Long-Term Chambers
    • Connect directly to the LI-8100A for single chamber long-term measurements or connect to the LI-8150-8 to multiplex. Includes two collars.
  • 4 8150-705 Cable/Hose Assembly, 15 m
    • For connecting the 8100-104 to the LI-8150-8.
  • 8100-704 Cable/Hose Assembly, 2 m
    • For connecting the 8100-104 to the LI-8100A for single chamber, long-term measurements.
  • 8150-770 AC Power Supply
    • For use with the LI-8150-8 when multiplexing.
  • 8150-706 DC Power Cable
    • Connect directly to the LI-8100A for single chamber long-term measurements or connect to the LI-8150-8 to multiplex. Includes two collars.
  • 8100-202 Soil Moisture Probe
    • For use with the LI-8100A and 8100-103 for survey measurements or 8100-104 for single chamber, long-term measurements.
  • 8100-201 Soil Temperature Probe
    • For use with the LI-8100A and 8100-103 for survey measurements only.
  • 8100-203 Soil Temperature Thermistor
    • For use with the LI-8100A and 8100-104 for single chamber, long-term measurements.
  • 4 8150-202 Soil Moisture Probe
    • Connects directly to the 8100-104; for use only if you multiplex.
  • 4 8150-203 Soil Temperature Thermistor
    • Connects directly to the 8100-104; for use only if you multiplex.
  • 8150-662 Profiling Kit
    • Connects to the LI-8150-08 (includes 4 ports).
  • 8100-664 Trace Gas Sampling Kit
    • Sample the same air stream used for CO2 flux for further trace gas analysis.
  • 5 8150-250 Bev-a-line
    • For use with the Profiling kit (250 ft total).
  • 8100-564 Windows Mobile Wireless Package
    • For use with any possible system configuration.
  • 3 6400-03 Battery
    • Used for the LI-8100A and 8100-103 only.
  • LI-6020 Battery Charger
    • Used to charge the 6400-03 batteries.
  • 8100-785 Two-Year Extended Warranty
    • Extends the standard one-year warranty for the LI-8100 to a total of three years.
  • 8150-8-785 Two-Year Extended Warranty
    • Extends the standard one-year warranty for the LI-8150-8 to a total of three years.

Future upgrades

Though you can expand the capabilities of the LI-8100TR at the same time you order it, there are a number of upgrades available as future teaching and research needs change.

  • Upgrade the 8 port Multiplexer (LI-8150-8) to a 16 port Multiplexer (LI-8150-16)
  • Add more long-term chambers and accessories as needed
  • Add 8100-104C Clear Chamber to study Net Carbon Exchange
  • Add the 8100-102 (10cm diameter) survey chamber
  • Save: If upgrades and/or additional chambers or any accessories are purchased with this package on the same order, a 10% discount will apply to the entire additional items purchased.

LI-8100TR Package Pricing & Questions

For pricing information or if you have any questions or you need a quote please contact our sales group at 800-447-3576 or email at envsales@licor.com.


Thank you for your request.

You will receive the an email shortly.

If you do not receive it within 24 hours or if you have any questions, please contact
LI-COR at 1-402-467-3576.


Get a Quote

Required fields must be completely filled out.



Buy Now

Scroll to Top