Ordering Information

LI-7200RS Enclosed CO2/H2O Analyzer

This configuration has the LI-7200RS without the 7200-101 Flow Module. A user-supplied pump or flow module is required. In addition to the gas analyzer, it includes:

  • LI-7550 Analyzer Interface Unit

  • The SMARTFlux System

  • Accessories Kit

    • Insulated intake tube
    • Inlet cap and screen
    • 2 Swagelok 2-micron dust filters
    • 5-meter cables (sensor head, RS-232 serial, auxiliary input, SDM cables)
    • 16GB industrial grade USB flash drive
    • Calibration fixture
    • Windows® software
    • Instruction manuals
Request a Quote

LI-7200RSD

This configuration has the LI-7200RS, 7200-101 Flow Module, and LI-610 Dew Point Generator. In addition to the gas analyzer, it includes:

  • LI-7550 Analyzer Interface Unit

  • 7200-101 Flow Module

  • The SMARTFlux System

  • LI-610 Portable Dew Point Generator

  • Accessories Kit

    • Insulated intake tube
    • Inlet cap and screen
    • 2 Swagelok 2-micron dust filters
    • 5-meter cables (sensor head, RS-232 serial, auxiliary input, SDM cables)
    • 16GB industrial grade USB flash drive
    • Calibration fixture
    • Windows® software
    • Instruction manuals
Request a Quote

Heated Intake Tube

The heated intake tube is recommended for humid environments.

  • 7200-050: This model is compatible with the LI-7200RS and LI-7550s with serial numbers AIU-1279 and greater.
  • 7200-040: This model is required for LI-7200s with LI-7550 serial numbers AIU-1278 and lower.
Request a Quote

LI-7200RSF

This configuration has the LI-7200RS and 7200-101 Flow Module. In addition to the gas analyzer, it includes:

  • LI-7550 Analyzer Interface Unit

  • 7200-101 Flow Module

  • The SMARTFlux System

  • Accessories Kit

    • Insulated intake tube
    • Inlet cap and screen
    • 2 Swagelok 2-micron dust filters
    • 5-meter cables (sensor head, RS-232 serial, auxiliary input, SDM cables)
    • 16GB industrial grade USB flash drive
    • Windows® software
    • Instruction manuals
Request a Quote

LI-7200 to LI-7200RS Upgrade

The factory upgrade converts an LI-7200 to an LI-7200RS. Includes a full factory recalibration, hardware components, and software.

Request a Quote

CH4, CO2 and H2O Flux Analyzer Packages

The GHG-2 package combines the LI-7700 and LI-7200RS at discount pricing. In addition to the gas analyzer, it includes:

  • LI-7700 Open Path CH4 Analyzer

  • LI-7550 Analyzer Interface Unit

  • 7200-101 Flow Module

  • The SMARTFlux System

  • Accessories Kit

    • 5-meter cables (sensor head, RS-232 serial, auxiliary input, SDM cables)
    • 16 GB industrial grade USB flash drive
    • Calibration fixture
    • Windows® software
    • Instruction manuals
Request a Quote

Sonic Anemometers

Sonic anemometers are available in combination with gas analyzer purchases.

Gill WindMaster™ Sonic Anemometer

Aluminum and carbon fiber construction. Includes the WindMaster™ (calibrated), carrying case, anemometer mount, serial communications cable, and analog outputs.

  • Output rate: 20 Hz
  • Wind speed range: 0-45 m/s
  • Wind speed resolution: 0.01 m/s
  • Wind speed accuracy: 1.5% RMS @ 12 m/s.
  • Direction range: 0-359°
  • Direction resolution: 0.1°
  • Direction accuracy: 2° @ 12 m/s.

Gill WindMaster™ Pro Sonic Anemometer

Stainless-steel construction. Includes the WindMaster™ Pro (calibrated), carrying case, anemometer mount, serial communications cable, and analog outputs.

  • Output rate: 32 Hz
  • Wind speed range: 0-65 m/s
  • Wind speed resolution: 0.01 m/s
  • Wind speed accuracy: <1.5% RMS @ 12 m/s
  • Direction range: 0-359°
  • Direction resolution 0.1°
  • Direction accuracy: 2° @ 12 m/s

Gill R3-50 Sonic Anemometer

Aluminum and carbon fiber construction. Includes the R3-50 (calibrated), carrying case, anemometer mount, and PCIA unit for analog output.

  • Output rate: 50Hz
  • Wind speed range: 0-45 m/s
  • Wind speed resolution: 0.01 m/s
  • Wind speed accuracy of <1% RMS
  • Direction range: 0-359°
  • Direction resolution 1°
  • Direction accuracy <±1° RMS

Gill HS-50 Sonic Anemometer

Stainless-steel construction. Includes the HS-50 (calibrated), carrying case, anemometer mount, and PCIA unit for analog output.

  • Output rate: 50Hz
  • Wind speed range: 0-45 m/s
  • Wind speed resolution: 0.01 m/s
  • Wind speed accuracy of <1%RMS
  • Direction range: 0-359°
  • Direction resolution of 1°
  • Direction accuracy <±1° RMS

Accessories and Replacement Parts