COVID-19 Update: We remain open and ready to help. Read More

Individual Components

8200-01S Smart Chamber, 20 cm

Includes spares kit, soil moisture/temperature probe, and three soil collars. Optional cable assemblies included based on gas analyzer configuration. Contact us for details.

8100-102 Survey Chamber, 10 cm

Includes gasket kit, spares kit, soil temperature probe and six soil collars.

8100-103 Survey Chamber, 20 cm

Includes gasket kit, spares kit, soil temperature probe and six soil collars.

8100-104 Long-Term Chamber

Includes gasket kit, spares kit and two soil collars.

8100-104C Clear Chamber

Includes gasket kit, spares kit and two soil collars.

LI-8100A Analyzer Control Unit

This is the system controller, gas analyzer, data logger, and wireless/networking interface (chambers, multiplexer, battery and battery charger not included).

    Includes:
  • Analyzer Control Unit
  • Auxiliary Sensor Interface
  • Serial Cable Interface
  • RS-232 Serial Cable
  • RS-232 to USB Adapter
  • Spares Kit
  • Compact Flash Memory Card
  • PC Card Adapter
  • Shoulder Strap Kit
  • Instruction Manual
  • TP-Link Wireless Router

LI-8150-8 8-Port Multiplexer

Connect up to eight Long-Term Chambers or gas sampling lines. Note: LI-8150 powers the LI-8100A Analyzer Control Unit when connected. (LI-8100A, Chambers, and Power Supply not included.)

    Includes:
  • 8-port Multiplexer
  • Spares Kit
  • Cable/Hose Assembly for connection to LI-8100A Analyzer Control Unit
  • 8150-706 DC Power Cable

LI-8150-16 16-Port Multiplexer

Connect up to 16 Long-Term Chambers or gas sampling lines. Note: LI-8150 powers the LI-8100A Analyzer Control Unit when connected. (LI-8100A, Chambers, and Power Supply not included.)

    Includes:
  • 16-port Multiplexer
  • Spares Kit
  • Cable/Hose Assembly for connection to LI-8100A Analyzer Control Unit
  • 8150-706 DC Power Cable

Accessories

  • Soil Temperature Probe (6000-09TC)
  • Soil Temperature Thermistor (8100-203)
  • Soil Moisture Probe (8100-202)

Survey and Long-Term Packages

LI-8100A-S1 Survey Package 1

A complete system for survey measurements using the 10 cm survey chamber.

    Includes:
  • LI-8100A Analyzer Control Unit
  • 8100-102 10 cm Survey Chamber
  • Three 6400-03 Batteries
  • Two LI-6021 Battery Chargers
  • 8100-205 Soil Moisture Probe
  • 6000-09TC Soil Temperature Thermocouple

LI-8100A-S2 Survey Package 2

A complete system for survey measurements using the 20 cm survey chamber.

    Includes:
  • LI-8100A Analyzer Control Unit
  • 8100-103 20 cm Survey Chamber
  • Three 6400-03 Batteries
  • Two LI-6021 Battery Chargers
  • 8100-205 Soil Moisture Probe
  • 6000-09TC Soil Temperature Thermocouple

LI-8100-NCE Net Carbon Exchange Package

Ideal for net carbon exchange measurements, this package includes one clear chamber with a variety of ancillary sensors.

    Includes:
  • LI-8100A Analyzer Control Unit
  • 8100-104C Clear Chamber
  • 8100-704 Cable/Hose Assembly
  • 8100-205 Soil Moisture Probe
  • 8100-203 Soil Temperature Thermistor Probe
  • LI-190R Quantum Sensor
  • Light Sensor Amplifier
  • 8100-604 Leveling Stake

LI-8100A-SL1 Survey and Long-Term Package

Ideal for gaining a basic understanding of spatial and diurnal variation.

    Includes:
  • LI-8100A Analyzer Control Unit
  • 8100-103 20 cm Survey Chamber
  • 8100-104 Long-Term Chamber
  • Three 6400-03 Batteries
  • Two LI-6021 Battery Chargers
  • 8100-205 Soil Moisture Probe
  • 8100-203 Soil Temperature Thermistor
  • 8100-704 Cable/Hose Assembly

Multiplexer Packages

LI-8100-P16 Sixteen Chamber Multiplexed Package

This is a 16-chamber system, complete with soil temperature sensors and the 16-port multiplexer. It provides the largest sample size.

    Includes:
  • LI-8100A Analyzer Control Unit
  • LI-8150-16 Multiplexer
  • Sixteen 8100-104 Long-Term Chambers
  • Sixteen 8150-705 Cable/Hose Assemblies
  • Sixteen 8150-203 Soil Temperature Thermistors
  • 8150-706 DC Power Cable
  • 8150-770 AC to DC Power Supply

LI-8100-P8 Eight Chamber Multiplexed Package

This is an 8-chamber system and 8-port multiplexer.

    Includes:
  • LI-8100A Analyzer Control Unit
  • LI-8150-8 Multiplexer
  • Eight 8100-104 Long-Term Chambers
  • Eight 8150-705 Cable/Hose Assemblies
  • Eight 8150-203 Soil Temperature Thermistors
  • 8150-706 DC Power Cable
  • 8150-770 AC to DC Power Supply

LI-8100-M1 Four Chamber Multiplexed Package

This is a 4-chamber system and 8-port multiplexer for long-term measurements. Ideal if you want to use up to 8 chambers at a later time or use the surplus ports for ancillary measurements such as profile sampling or flask sampling.

    Includes:
  • LI-8100A Analyzer Control Unit
  • LI-8150-8 Multiplexer
  • Four 8100-104 Long-Term Chambers
  • Four 8150-705 Cable/Hose Assemblies
  • 8150-706 DC Power Cable
  • Auxiliary sensors sold separately

LI-8100-M2 Four Chamber Multiplexed Package

This is a 4-chamber system and 16-port multiplexer for long-term measurements. Ideal if you want to use up to 16 chambers at a later time or use the surplus ports for ancillary measurements such as profile sampling or flask sampling.

    Includes:
  • LI-8100A Analyzer Control Unit
  • LI-8150-16 Multiplexer
  • Four 8100-104 Long-Term Chambers
  • Four 8150-705 Cable/Hose Assemblies
  • 8150-706 DC Power Cable
  • Auxiliary sensors sold separately

LI-8150-M3 Four Chamber Multiplexed Package

This is a 4-chamber system and 8-port multiplexer. Ideal if you already have an Analyzer Control Unit and you want to use up to eight chambers at a later time or use the surplus ports for ancillary measurements such as profile sampling or flask sampling.

    Includes:
  • LI-8150-8 Multiplexer
  • Four 8100-104 Long-Term Chambers
  • Four 8150-705 Cable/Hose Assemblies
  • 8150-706 DC Power Cable
  • Auxiliary sensors sold separately

LI-8150-M4 Four Chamber Multiplexed Package

This is a 4-chamber system and 16-port multiplexer. Ideal if you already have an Analyzer Control Unit and want to use up to 16 chambers at a later time or use the surplus ports for ancillary measurements such as profile sampling or flask sampling.

    Includes:
  • LI-8150-16 Multiplexer
  • Four 8100-104 Long-Term Chambers
  • Four 8150-705 Cable/Hose Assemblies
  • 8150-706 DC Power Cable
  • Auxiliary sensors sold separately

LI-8100TR Automated Soil CO2 Flux and Atmospheric Monitoring System

Teaching/Research Package — Educational (Available in North America Only).

This flexible teaching package provides everything you need for survey, long term, and profile measurements.

    Includes:
  • LI-8100A Analyzer Control Unit
  • LI-8150-8 Multiplexer
  • 8100-103 20 cm Survey Chamber
  • 8100-704 Cable/Hose Assembly
  • Four 8100-104 Long-Term Chambers
  • Four 8150-705 Cable/Hose Assemblies
  • Four 8150-203 Soil Temperature Thermistors
  • 8100-205 Soil Moisture Probe
  • 8100-704 Cable/Hose Assembly
  • 8150-662 Profiling Kit
  • 8100-664 Trace Gas Sampling Kit
  • Five 8150-250 Bev-A-Line® Tube Rolls
  • 8150-706 DC Power Cable
  • 8150-770 AC to DC Power Supply
  • Three 6400-03 Batteries
  • Two LI-6021 Battery Chargers
  • Three 8100-510 DVD Training Sets
  • Two year extended warranties for the LI-8100A and LI-8150-8

Application Accessories

CO2 Mapping Kit (8100-405)

Includes GPS receiver, cable assembly, mounting bracket, quick connect fitting, and Bev-A-Line® tubing. Designed for use with the LI-8100A Analyzer Control Unit for mapping ground level CO2 concentrations, or for use with survey systems.

8 Port Flask Sampling Kit (8150-670-8)

Includes all hardware needed to connect up to 8 flasks to the 8-port Multiplexer.

16 Port Flask Sampling Kit (8150-670-16)

Includes all hardware needed to connect up to 16 flasks to the 16-port Multiplexer.

Trace Gas Sampling Kit (8100-664)

Used to collect samples from the same air stream used to measure CO2 flux for further trace gas analysis. Call LI-COR for details.

Profiling Kit (8150-662)

For atmospheric profiling studies using the LI-8150 Multiplexer and LI-8100A Analyzer Control Unit. Includes hardware for four ports; 8150-250 Bev-A-Line® tubing sold separately. Call LI-COR for details.

  • Soil Temperature Probe (6000-09TC)
  • Soil Temperature Thermistor (8100-203)