Thanks for your request

Contact us at envsupport@licor.com if you are unable complete your request.

Smart Chamber Embedded Software

We are unable to display the form due to your browser’s privacy settings. Please use a different browser or adjust your browser’s privacy settings. If you need further assistance, please contact us.

LI-8250 Embedded Firmware

We are unable to display the form due to your browser’s privacy settings. Please use a different browser or adjust your browser’s privacy settings. If you need further assistance, please contact us.

LI-8100A PC and Embedded Software

We are unable to display the form due to your browser’s privacy settings. Please use a different browser or adjust your browser’s privacy settings. If you need further assistance, please contact us.

SoilFluxPro Software

We are unable to display the form due to your browser’s privacy settings. Please use a different browser or adjust your browser’s privacy settings. If you need further assistance, please contact us.

LI-8100/A Windows Mobile and Palm Software

We are unable to display the form due to your browser’s privacy settings. Please use a different browser or adjust your browser’s privacy settings. If you need further assistance, please contact us.

SoilFluxPro Software

SoilFluxPro Powerful and easy-to-use data management and optimization software

SoilFluxPro streamlines the management of large datasets and includes post-processing tools to refine your soil gas flux results. It is developed exclusively for and included with LI-COR soil gas flux systems.

Why choose SoilFluxPro Software?

Fine-tune soil gas flux results

Compute fluxes and perform quality assurance checks for both long-term and survey datasets. SoilFluxPro allows you to revise the parameters of large datasets and instantly see the effect on your flux calculations. Recalculate multiple datasets at a time and use what you learn to optimize your measurements.

Integrate complex datasets

The Smart Chamber and LI-8250 Multiplexer both integrate analyzers of various gas species, including third-party analyzers. SoilFluxPro carries that integration through post-processing. Compute fluxes of trace gases and isotopologues using complex datasets imported from LI-COR and third-party analyzers.

Map soil gas fluxes

Each measurement is tagged with GPS location data. SoilFluxPro uses that data to create a .kml file with concentrations and fluxes. You can then export that .kml file to a mapping service to generate visualizations.

New in SoilFluxPro Version 5.3

SoilFluxPro v5.3 includes powerful new advanced guidance tools for deadband and stop time analysis, the ability to save your favorite displays and link them to output when exporting data, and more.

Improved, automated guidance for deadband and stop time

In SoilFluxPro v5.3, guidance can be applied to multiple observations, rather than just one as in previous versions. SoilFluxPro determines the deadband and stop time using data from multiple options with a method based on diffusion theory.

For Deadband Analysis, SoilFluxPro calculates the point at which the flux is least sensitive to the start time and suggests the average value for that period as the deadband.

For Stop Time Analysis, SoilFluxPro calculates the point at which to stop the measurement to ensure that computations do not include the effects of lateral diffusion.

This function works best on high concentration gases such as CO2. The more observations included in the analysis, the better the result.

SoilFluxPro Screenshot
SoilFluxPro Deadband Analysis. The green line shows the suggested deadband (19.5), the gray shows the deadband currently in use (35). To make the calculation, the software used CO2 concentration data from 372 observations from one port of an LI-8250 Multiplexer using an LI-7810 CH4/CO2/H2O Trace Gas Analyzer.

Save display favorites and more

With SoilFluxPro v5.3, you can save display settings—which parameters to show in columns—as favorites. The addition of this feature also allows you to export a set of parameters based on the display.

The Repair tool has been improved to allow you to filter erroneous values and replace them with those interpolated from adjacent values. You can configure the filtering with minimum and maximum thresholds.

New filter tools in Recompute give you the ability to manually delete an outlier on a plot, and recompute the charted data. The tools include rectangle and polygon selection, undo, and restore points.

In SoilFluxPro v5.3, you can pop out and expand windows for a better view of flux plots and computations.

For detailed information on these new features and how to use them, read What's New in SoilFluxPro v5.3 on the support site.

Get started using SoilFluxPro for free.

Download v5.3 for Windows Download v5.3 for macOS