TriSonica®

Specifications

LI-550 TriSonica Mini

  • Power Supply Voltage: 5 - 32 VDC
  • Power: 400 mW
  • Operating Environment:
    • Altitude: Up to 5000 meters
    • Temperature: -20 to 72 °C
    • Relative Humidity: 0 to 100% (non-condensing). System may require reset if condensation accumulates within enclosure.
    • The 550USB is not rated for outdoor use.
  • Transient Overvoltage: Category I
  • Temporary Overvoltage: 40 Volts
  • Pollution Tolerance: Level 3 (enclosure must be intact and humidity vent in good condition)
  • Sampling Frequency: 40 Hz maximum
  • Ultrasonic Frequency: 60 kHz ±5 kHz
  • Weight: 50-67 grams
  • Size:
    • LI-550F: 9.1 x 9.1 x 5.2 cm
    • LI-550P: 8 × 8 × 7.3 cm
  • Digital Output: RS-232, RS-422, UART-3V
    • LI-550F: RS-232
    • LI-550P: RS-232, RS-422, UART-3V
  • Output Rate: 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz, or 40 Hz
  • Wind Direction Measurements:
    • Resolution (u/v/w): 1.0°
    • Range (u/v): 0 to 359°
    • Accuracy (u/v): ±1.0°
    • Range (w): ±15° from the horizontal plane of the instrument
    • Accuracy (w): 0.2 m/s
  • Humidity Sensor:
    • Range: 0 to 100% RH
    • Resolution: 0.01%
    • Accuracy: ±3%
  • Pressure Sensor:
    • Range:50 to 115 kPa
    • Resolution: 0.01 kPa
    • Accuracy: ±1.0%
  • Temperature Measurements:
    • Range:-20 °C to 72 °C
    • Resolution: 0.01 °C
    • Accuracy: ±2.0 °C
  • Magnetometer:
    • Range (u, v, w): ±50 Gauss
    • Heading Accuracy: ±5°
  • Accelerometer:
    • Range (u, v, w): ±2 g
    • Tilt (pitch, roll): ±90°

Specifications subject to change without notice.

LI-560 TriSonica Sphere

  • Power Supply Voltage: 5 - 32 VDC
  • Power: 600 mW (500mW typical)
  • Operating Environment:
    • Altitude: Up to 5000 meters
    • Temperature: -20 to 72 °C
    • Relative Humidity: 0 to 100% (non-condensing)
    • The 550USB is not rated for outdoor use.
  • Transient Overvoltage: Category I
  • Temporary Overvoltage: 40 V
  • Pollution Tolerance: Level 3 (enclosure must be intact)
  • Sampling Frequency: 100 Hz maximum
  • Ultrasonic Frequency: 60 kHz ±5 kHz
  • Weight: 225 grams
  • Size: 10.2 x 10.2 x 24.9 cm
  • Digital Output: RS-232, RS-422, UART-3V
  • Output Rate: 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz, 25 Hz, 50 Hz, 100 Hz
  • Wind Speed Measurements:
    • Range: 0-50 m/s
    • Resolution: 0.01 m/s
    • Accuracy: (0-10 m/s): ±1%*
    • Accuracy: (11-30 m/s): ±1%
    • Accuracy: (31-50 m/s): ±2%
    • *Averaged over 10 seconds
  • Wind Direction Measurements:
    • Range (u/v): 0-359°
    • Range (w): ±60°
    • Resolution: 1.0°
    • Accuracy: ±1.0°
    • Accuracy: (31-50 m/s): ±2%
  • Temperature Measurements:
    • Range: -20 °C to 72 °C
    • Resolution: 0.01 °C
    • Accuracy: ±2.0 °C
  • Accelerometer:
    • Range (u, v, w): ±2 g
    • Tilt (pitch, roll): ±90°

Specifications subject to change without notice.

LI-570 Data Logger

  • Power Supply Voltage: 10 - 54 VDC
  • Power: 400 mW when no sensor is connected; up to 12 W maximum
  • Environment: Suitable for outdoor use in wet locations
  • Altitude: Up to 5000 meters
  • Temperature: -20 to 50 °C
  • Relative Humidity: 0 to 100%.
  • Transient Overvoltage: Category II
  • Temporary Overvoltage: 60 V
  • Pollution Tolerance: Level 3 (enclosure must be intact and in good condition)
  • Four Serial Ports for TriSonica® Anemometers:
    • UART-TTL or EIA232 voltage level
    • Configurable baud rate and parity
    • 12V output to power TriSonica® sensors
    • Trigger output to synchronize multiple pipe-mount type sensors
  • Instrument Ports:
    • LI-550P and LI-560 trigger output
    • RS-232
  • GPS Port and External Radio Port:
    • NMEA0183 GPS
    • TTL-UART
    • I2C
    • JST 6-pin GH connector
    • GPS can be timing standard
  • MicroSD Card Storage:
    • Formats: FAT16, FAT32, exFAT
    • Maximum card capacity: >32 GB
  • Data Sampling:
    • Maximum scan rate: 100 Hz
    • Adjustable sampling rates
    • User-definable response for missing data
  • Real-time clock with time tagging option
  • External connections ESD protected
  • Weight: 450 g (16 oz.)
dimensions of TriSonica LI-570-4

Specifications subject to change without notice.