User-settable constants

Table 1‑1. User-settable constants available in BiometConstants.
Field Value (default) Description
BiometPackage 100 Sensor package identifier (100, 101, 102, or 103).
AveragePeriod 60 Time period over which to average sensor data in seconds.
ScanInterval 5 How often to sample the sensors in seconds. Note that the HydraProbes require a 3-second warm up before each sampling event.
UsePublicVars 0 Flag to set raw variables as public or not: 1 = public, 0 = not public
LogBiomet
Data
9999 Number of records to keep in Biomet data table.
LogControl
Flags
1 Number of records to keep in ControlFlags data table.
SHF1Sens 60.01 Sensitivity for soil heat flux plate 1 in uV/W/m2 (unique value for each soil heat flux plate).
SHF2Sens 60.01 Sensitivity for soil heat flux plate 2 in uV/W/m2 (unique value for each soil heat flux plate).
SHF3Sens 60.01 Sensitivity for soil heat flux plate 3 in uV/W/m2 (unique value for each soil heat flux plate).
SHF1RSelf 100.01 Self-resistance for soil heat flux plate 1 in Ohms (unique value for each soil heat flux plate).
SHF2RSelf 100.01 Self-resistance for soil heat flux plate 2 in Ohms (unique value for each soil heat flux plate).
SHF3RSelf 100.01 Self-resistance for soil heat flux plate 3 in Ohms (unique value for each soil heat flux plate).
CompResistor 10.01 Resistance of the completion resistors used with self-calibrating soil heat flux plates in Ohms.
CalDuration 3 How many minutes to actively heat the soil heat flux plates during calibration.
CalInterval 6 How often to calibrate self-calibrating heat flux plates in hours.
SoilType 3 Soil type ID: 1 = sand, 2 = silt, 3 = clay, 4 = loam.
HydraStart
Address
1 Address of the first HydraProbe. Note that the program can accommodate up to 3 HydraProbes using sequential addresses.
HydraStop
Address
3 Address of the last HydraProbe.
LI190Mult -200.01 Multiplier for the LI-190 or LI-190R.
LI200Mult -100.01 Multiplier for the LI-200 or LI-200R.
Pyranometer
UpSens
15.01 CNR4 upper pyranometer sensitivity (unique value for each net radiometer).
Pyranometer DownSens 15.01 CNR4 lower pyranometer sensitivity (unique value for each net radiometer).
Pyrgeometer
UpSens
8.01 CNR4 upper pyrgeometer sensitivity (unique value for each net radiometer).
Pyrgeometer
DownSens
8.01 CNR4 lower pyrgeometer sensitivity (unique value for each net radiometer).
CNR4Shunt 1000 Resistance of the CNR4 temperature sensor shunt resistor in Ohms.
HeatStartTime 20:00 Turn on time for the optional CNF4 heater.
HeatStopTime 08:00 Turn off time for the optional CNF4 heater.
VentStartTime 20:00 Turn on time for the optional CNF4 ventilator.
VentStopTime 08:00 Turn off time for the optional CNF4 ventilator.