List of outputs

This section provides a summary of the output files generated by EddyPro. Some of the files described below may not be included in your output folder, depending upon the files specified in the Output Files tab (see Output files). A full set of output files is shown in Figure 3‑2.

Figure 3‑2. Output folder created by EddyPro when all outputs are selected.

Table 3‑1 provides more details about the folders and files created by EddyPro.

Table 3‑1. Typical outputs from an EddyPro run with advanced settings.
File/Folder Name Description
eddypro_binned_cospectra Folder containing binned cospectra files (see Binned cospectra outputs).
eddypro_binned_ogives Folder containing binned ogives files (see Binned ogives).
eddypro_full_cospectra Folder containing full cospectra files (see Full cospectra).
eddypro_spectral_analysis Folder containing spectral analysis files (see Spectral analysis).
eddypro_stats Folder containing statistical output files (see Stats).
eddypro_user_stats Folder containing user statistics files.
eddypro_OutputID_essentials_yyyy-mm-ddThhmmss.csv Intermediate flux results that have not been corrected. EddyPro uses this file when you want to quickly reprocess data. See Using results from previous runs for more information.
eddypro_OutputID_biomet_yyyy-mm-ddThhmmss.csv Summarized output variables.
eddypro_OutputID_fluxnet_yyyy-mm-ddThhmmss.txt File conforming FLUXNET and AmeriFlux FP-In Standards for labels, units and format. Features new output variables, including many intermediate results, statistics on all high-frequency variables, covariances between all high-frequency variables, biomet mean values and metadata, as well as results of new implementations
eddypro_OutputID_full_output_yyyy-mm-ddThhmmss.csv Final flux results.
eddypro_OutputID_metadata_yyyy-mm-ddThhmmss.csv A summary of information stored in each of the metadata files for the project.
eddypro_OutputID_qc_details_yyyy-mm-ddThhmmss.csv A summary of errors and tests for each 30 minute data set.
processing_yyyy-mm-ddThhmmss.eddypro EddyPro project file.

Binned cospectra outputs

This folder includes one .csv file for each 30 minute dataset. See Calculating spectra, cospectra, and ogives for more information.

Binned ogives

This folder includes one .csv file for each 30 minute dataset. See Calculating spectra, cospectra, and ogives for more information.

Full cospectra

This folder includes one .csv file for each 30 minute dataset. See Calculating spectra, cospectra, and ogives for more information.

Spectral analysis

This folder includes spectra and cospectra data files in .csv format. It also includes a spectral assessment file that can be used to reprocess a data set if the spectral assessment file applies. See Calculating Spectral correction factors for more information.

Stats

The stats folder includes a .csv file for each level of processing.

User stats

The user stats folder includes a .csv file for each level of processing.