Useful Part Numbers

Quantity is “1 each” unless otherwise stated.

Entire System Part Number
Standard spare parts kit 9964-015
Items for Chemical Tubes Part Number
Drierite desiccant (1 lb bottle)a 622-04299
Soda lime - wet (450g bottle) 9964-090
Ascarite II (500g bottle) 9970-022
Air flow muffler 300-03707
Small O-ring (seals air passage to console) 192-02597
Large O-ring for end caps 192-04291
Chemical tube assembly (entire) 9964-021
Threaded tube only 6564-076
Bottom end cap 6564-071
Labels for desiccant and soda lime tubes 250-04296
Tygon tubing (material for small bypass tubes) 222-00302
Flow adjust knob 9864-075
Set screw for flow adjust knob 142-00109
Battery Items Part Number
Battery 6400-03
10 Amp fuse for 6400-03 battery 438-03142
Male connector (as on the battery) 318-02031
Female connector (as on the console) 318-02030
Cable (5 ft) and connectors for charger - console 9960-062
Cable (10ft) and connector for external battery 9960-120
Items for Air Flow Part Number
Balston air filter 300-01961
1/8” ID quick coupler, female 300-04269
1/8” ID quick coupler, male 300-04270
Replacement air pump 286-04198
Air pump repair kit 6400-907
Bev-a-line tubing (per foot) (1 box = 50ft) 222-01824
Lower chamber exhaust tube 6564-154
1/4” OD Quick Connect straight union 300-03123
1/4” OD Quick Connect “Y” 300-03367
Console Part Number
Clock battery (keeps time while power off) 442-03791
3A, 250V, fast blow (5 x 20 mm) 439-04215
5A, 125V, fast blow (5 x 20 mm) 439-04214
1A, 250V, fast blow (5 x 20 mm) 439-04216
Screws (16 required) for holding bottom shell 122-00007
Items for Chambers Part Number
4-40, 1.75" hex screw for attaching chamber 140-04251
Leaf Temperature Thermocouple 6400-04
Propafilm (10" wide, order by length) 250-01885
Double sided tape (per foot) 212-04341
Gaskets: 2x3 chamber and 3-hole (10 sets) 6400-30
Gaskets: 2x6 chamber and 3-hole (10 sets) 6400-32
Gaskets: 6400-05 Conifer chamber (5 sets) 6400-31
Gaskets: 6400-02B LED source. Includes 20 white gaskets, 5 black neoprene gaskets for the lower chamber, and 5 3-hole gaskets. 6400-33
Gaskets: 6400-40 LCF 6400-41
Needle holding gaskets (5 sets) 6400-34
Teflon tape (3.5" wide, order by length) 212-02314
Upper half of std. 2x3 chamber 9964-028
Lower half of std 2x3 chamber 9964-029
Upper half of 2x6 chambers 9964-052
Lower half of clear bottom, 2x6 needle chamber 9964-051
Lower half of 2x6 narrow chamber 9964-050
O-ring (smaller) for outer air passage 192-04357
O-ring (larger) for inner air passage 192-04356
6400-17: seal for 2.5 inch pots 6564-279
6400-17: seal for Conetainers 192-09261
6400-17: O-ring for chamber top 192-09262
Items for the CO2 Mixer Part Number
Entire source assembly for 12 gram cartridges 9964-026
Connector block for CO2 tanks 9964-033
12 gram CO2 cartridges (25)  
(includes 9964-041) 9964-037
Spare parts kit for CO2 mixer 9964-039
25 little O-rings, and a filter (Spares kit) 9964-041
Flow restrictor assembly 9964-042
Large O-ring between source and console 192-01919
Items for Sensor Head / IRGA Part Number
Latch repair kit (has 6564-057 installed) 6400-903
Chamber catch rod (wire only) 6564-057
Chamber tension adjustment assembly 6400-908
Log switch replacement kit 6400-904
Fan motor (field installation version) 6400-902
Sensor head manifold 9864-033
Vinyl manifold gasket (top of sample cell) 6564-022
Screws for sensor head manifold 140-04234
Vinyl gasket (mirrors) 6564-021
Screws for chamber mirrors 140-04236
Connector screws for chamber/IRGA cables 314-04913
Chamber handle screws 122-02284
Tripod bracket screws 122-04276
Internal scrubber bottles (2), with chemicals 6400-950