Tips for Using Modular Terminals
The Biomet station includes DIN-rail mounted modular terminals to provide electrical connections for sensors, switches, and resistors. Two types of modular terminals are included: 2-position terminals that have two electrically connected terminals, and 4-position terminals that have 4 electrically connected terminals. Red terminals are power (+), blue are ground (-), and gray are signal or auxiliary. The modular terminals can accommodate wires from 26 AWG to 14 AWG.
Terminals for Incoming Power
| 1, 2, 3 |
System power (+) |
Power in terminals; electrically connected |
| 4 |
System ground |
System ground terminal |
| 5, 6, 7 |
System power (-) |
Power in terminals; electrically connected |
Terminals for Sensors and Components
| 8 |
Power (-) |
Power to instruments |
| 9, 10, 11 |
Power (+) |
24 or 12 VDC power to instruments |
| 12, 13, 14 |
Power (+) |
12 VDC power to ancillary devices |
| 15 |
SDI-12 ground |
Used with Stevens Hydra Probe II |
| 16 |
SDI-12 power |
Used with Stevens Hydra Probe II |
| 17 |
SDI-12 signal |
Used with Stevens Hydra Probe II |
| 18, 19, 20 |
Power (-) |
Power for datalogger, relay, and CNF4 |
| 21, 22, 23 |
Power (+) |
12 VDC power for datalogger, relay, and CNF4 |