Status dictionary map
                                                    The table below shows the status values that can be monitored via ASSIGN.
| Type | Group | Name | Description | 
|---|---|---|---|
| Auxiliary | Analog | AuxPwr | Voltage for the auxiliary power port in head | 
| Dac1 | D/A #1 (pin 2) setting | ||
| Dac2 | D/A #2 (pin 3) setting | ||
| Dac3 | D/A #3 (pin 4) setting | ||
| Dac4 | D/A #4 (pin 5) setting | ||
| Digital | ADC1Pullup | ADC Chan1 pullup (pin 21) | |
| Dio1 | Pin 6: low, high, input | ||
| Dio2 | Pin 7: low, high, input | ||
| Dio3 | Pin 8: low, high, input | ||
| Dio4 | Pin 9: low, high, input | ||
| Dio5 | Pin 10: low, high, input | ||
| Dio6 | Pin 11: low, high, input | ||
| Dio7 | Pin 12: low, high, input | ||
| Dio8 | Pin 13: low, high, input | ||
| Excite5 | 5V excitation (pin 25) | ||
| GPIO | State summary (pins 13-6) | ||
| GPIOdir | Direction summary (pins 13-6) | ||
| Power12 | 12V power (pin 23) | ||
| Power5 | 5V power (pin 14) | ||
| Env Controls | CO2 | CO2:Label | CO2_r, CO2_s, or blank | 
| CO2:Percent | CO2 injector target (if manual) % | ||
| CO2:Scrub | auto, on, off | ||
| CO2:SetPoint | CO2 setpoint (if auto) mol mol | ||
| CO2:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| Fan | Fan:Percent | Manual set point | |
| Fan:SetPoint | Automatic target (target units) | ||
| Fan:SetPoint_rpm | Automatic target (rpm) | ||
| Fan:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| Fan:Target | (if auto) RPM or BLC | ||
| Flow | Flow:Percent | Flow setpoint (if manual) mol s | |
| Flow:Pump | auto, high, medium, low, minimum, off | ||
| Flow:SetPoint | Flow setpoint (if auto) mol s | ||
| Flow:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| H2O | H2O:PercentD | % Desiccant (manual) | |
| H2O:PercentH | % Humidifier (manual) | ||
| H2O:SetPoint | H2O setpoint (target units) | ||
| H2O:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| H2O:Target | H2O_r, H2O_s, RH air, etc. | ||
| H2O:Teff | Coolest temp in chamber | ||
| H2O:TlowLab | Label of coolest chamber temp | ||
| Env Controls (continued) | Light | Con:ColorMix | Mix resulting from color spec | 
| Con:ColorSpec | Color specification | ||
| Con:Control | off, setpoint, percent or test | ||
| Con:Info | Console light source info | ||
| Con:Percent | Manual %s: red blue farred | ||
| Con:Setpoint | Actinic setpoint mol m s | ||
| Con:Status | Con: 0=off, 1=manual, 2=off target, 3=on target | ||
| Con:Trans | Transmittance | ||
| Flr:ColorMix | Mix resulting from color spec | ||
| Flr:ColorSpec | Color specification | ||
| Flr:Control | off, setpoint, percent or test | ||
| Flr:Info | Flr info | ||
| Flr:Percent | Manual %s: red blue farred | ||
| Flr:Setpoint | Actinic setpoint mol m s | ||
| Flr:Status | Flr: 0=off, 1=manual, 2=off target, 3=on target | ||
| Flr:Trans | Transmittance | ||
| Head:ColorMix | Mix resulting from color spec | ||
| Head:ColorSpec | Color specification | ||
| Head:Control | off, setpoint, percent or test | ||
| Head:Info | Head lightsource info | ||
| Head:Percent | Manual %s: red blue farred | ||
| Head:Setpoint | Actinic setpoint mol m s | ||
| Head:Status | Head: 0=off, 1=manual, 2=off target, 3=on target | ||
| Head:Trans | Transmittance | ||
| Env Controls (continued) | Pressure | Press:Percent | Press setpoint (if manual) mol s | 
| Press:SetPoint | Flow setpoint (if auto) mol s | ||
| Press:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| Temp | Temp:Hold | Tleaf control suspended (chamber open) | |
| Temp:SetPoint | Automatic setpoint | ||
| Temp:Status | 0=off, 1=manual, 2=off target, 3=on target | ||
| Temp:T2use | 0=none or out, 1=in, 2=avg | ||
| Temp:Target | Txchg, Tair, Tleaf | ||
| Temp:TleafOp | Tleaf control option value | ||
| Temp:TleafOpID | Tleaf control option ID | ||
| Log Options | Flr | FlrOpt:Action | 0=None, 1=Flash, 2=Flash+Dark | 
| FlrOpt:Auto | Threshold for Automatic MPF | ||
| FlrOpt:FlashType | 0=Auto, 1=RF, 2=MPF, 3=Ind | ||
| FlrOpt:MinFlash | Minimum flash interval | ||
| Match | MchOpt:CO2Change | Match opt: CO2 changed > | |
| MchOpt:CO2Delta | Match opt: |CO2| < | ||
| MchOpt:Choice | Never match / Always match / Only match if | ||
| MchOpt:ChoiceNum | Match: 0=Never, 1=Always, 2=If | ||
| MchOpt:Elapsed | Match opt: elapsed time > | ||
| MchOpt:H2OChange | Match opt: H2O changed > | ||
| MchOpt:H2ODelta | Match opt: |H2O| < | ||
| Standard | LogOps:MakeExcel | Also create Excel log file | |
| LogOpts:AvgTime | Additional averaging time | ||
| LogOpts:Beep | Beep on log | ||
| Matching | Auto Config | Mch:AvgTime | Auto match stats averaging time | 
| Mch:CO2 limit | CO2 delta rate of change green light threshold | ||
| Mch:H2O limit | H2O delta rate of change green light threshold | ||
| Mch:Timeout | Auto mode timeout time | ||
| Status | Mch:AutoFrac | Fraction complete of an automatic match | |
| Mch:LogLabel | Match label (shown on log button) | ||
| Mch:Message | Result of previous match | ||
| Mch:State | 0=inactive, 1=manual, 2=automatic | ||
| Mch:ddCdt | CO2 stability during match | ||
| Mch:ddHdt | H2O stability during match | ||
| Misc | Logging | LOG:FileName | Name of current log file | 
| LOG:FileTS | Timestamp of last opened log file | ||
| LOG:IsFileOpen | Is a log file open? | ||
| LOG:LastRem | Latest logged remark | ||
| LOG:ObsCount | Observations logged | ||
| LOG:State | Is a log event active? | ||
| Power | PowerState | on, standby, sleep | |
| PowerValue | 0=On, 1=Standby, 2=Sleep | ||
| Stability | Stab:Stable | Number of items checked for stability | |
| Stab:State | Stability state: Stable/Total | ||
| Stab:Total | Number of items stable | 
 
                                            