Control picker
When choosing controls, either in Auto Controls or Programs, you select a Group, and from that group, a variable Name. The groups and names are available for Auto Controls and Programs. Several Programs are capable of setting constants and settings, and those groupings are shown in Table 3‑6.
Automatic chamber environment controls
Table 3‑5. Environmental controls that can be selected in the AutoEnv interface.
| Env Aux Controls |
AuxPwr |
Auxiliary power in head (0 to 19 V) |
| Dac1 |
DAC 1 (pin 2) -5 to +5 V |
| Dac2 |
DAC 2 (pin 3) -5 to +5 V |
| Dac3 |
DAC 3 (pin 4) -5 to +5 V |
| Dac4 |
DAC 4 (pin 5) -5 to +5 V |
| Env CO2 Controls |
CO2_% |
Injector control 0 to 100% |
| CO2_r |
Reference CO2 |
| CO2_s |
Sample CO2 |
| Env Fan Controls |
Fan_% |
Fan power (0 to 100%) |
| Fan_blc |
Boundary layer conductance target (mol m-2 s-1) |
| Fan_rpm |
Fan speed (rpm) |
| Env Flow Controls |
Flow_% |
Percent flow to chamber (0 to 100%) |
| Flow |
Flow to chamber (µmol s-1) |
| Env H2O Controls |
Desiccant_% |
Desiccant (only) control (0 to 100%) |
| H2O_% |
Full desiccant to full humidifier (-100 to 100%) |
| H2O_r |
Reference H2O (mmol mol-1) |
| H2O_s |
Sample H2O (mmol mol-1) |
| Humidifier_% |
Humidifier (only) control (0 to 100%) |
| RH_air |
Chamber RH (0 to 10%) |
| SD_air |
Saturation Deficit (kPa) |
| VPD_leaf |
VPD of leaf (kPa) |
| Env Light Controls |
Q_All |
All attached light sensors |
| Q_Console |
Console light source only |
| Q_Flr |
Fluorometer only |
| Q_Head |
Head light source only |
| Qin |
All light sources contributing to Leaf Q |
| Env Pressure Controls |
Pressure |
Chamber over pressure (kPa) |
| Pressure_% |
Overpressure valve (0 to 100%) |
| Env Temperature Controls |
Tair |
Chamber air temperature |
| Tleaf |
Leaf temperature |
| Txchg |
Heat exchanger temperature |
Constants available in control loops
Table 3‑6. Environmental constants that can be changed via the MCLoop interface.
| Env Color Controls |
Color_All |
All attached sources |
| Color_Con |
Console light source |
| Color_Flr |
Fluorometer |
| Color_Head |
Head light source |
| Color_Qin |
All sources contributing to Leaf Q |
| Flr Constants |
FLR:Adark |
Dark respiration rate |
| FLR:Fm |
Maximal fluorescence |
| FLR:Fo |
Minimal fluorescence |
| FLR:PS2/1 |
Ratio PS2 to PS1 |
| Flr Dark Settings |
DARK:After |
Far red off _ secs after actinic off |
| DARK:Before |
Far red on _ secs after actinic off |
| DARK:Duration |
Actinic off duration |
| DARK:FarRed target |
Far red target |
| Flr Induct Settings |
IND:Duration |
Flash duration |
| IND:Red target |
Red flash target |
| Flr MPF Settings |
MPF:Phase 1 |
Phase 1 duration |
| MPF:Phase 2 |
Phase 2 duration |
| MPF:Phase 3 |
Phase 3 duration |
| MPF:Ramp |
Percent ramp |
| MPF:Red target |
Red flash target |
| Flr RF Settings |
RF:Duration |
Flash duration |
| RF:Red target” |
Ref flash target |
| Gas Exchange Constants |
Const:Custom |
Custom BLC |
| Const:Geometry |
0=broadleaf, 1=needle, 2=custom |
| Const:K |
Stomatal ratio |
| Const:S |
Leaf area (or Mass) |
| Leaf Temp Constants |
LTConst:deltaTw |
Wall - Air temp difference |
| LTConst:fT1 |
T1 weighting |
| LTConst:fT2 |
T2 weighting |
| LTConst:fTeb |
EB weighting |
| System Constants |
SysConst:AvgTime |
Average time |
| SysConst:Oxygen |
Oxygen percentage |
| User Defined Constants |
? |
whatever is defined |