Manuals
LI-7500 CO2/H2O Analyzer Instruction Manual
Instruction Manual for the original LI-7500.
Using the LI-7500A/RS? Look here instead.
Software
LI-7500 Open Path CO2/H2O Analyzer Instrument (Embedded) Software v3.0.1
Instrument (embedded) software for the LI-7500 Open Path CO2/H2O Analyzer.
LI-7500 Open Path CO2/H2O Analyzer Windows Interface Software v3.0.2
Windows interface software for the LI-7500 Open Path CO2/H2O Analyzer.
Videos
Frequently Asked Questions
We have examined many different USB adapters and found the type that we sell to work best with all of our instruments. Other adapters may work, but they may not.
We can only guarantee the FTDI adapter that we sell. It is included with many of the LI-COR instruments that require serial communication with a computer. We have found that some third-party USB adapters (Prolific, for example) do not accurately transmit all the data from the instrument to the computer, or vice versa. You should use an adapter with an FTDI chipset, and Belkin and Keyspan adapters typically work well with our instruments too.
All Documents
| Summary | ||
|---|---|---|
| 7500-600 LI-7500 Head Upgrade Kit instructions | Instructions for upgrading the LI-7500 sensor head to the LI-7500A. | install guide |
| LI-7500 CO2/H2O Analyzer Software Update Instructions for Instrument (embedded) and Windows Interface Software | Instructions for updating the instrument (embedded) and Windows interface software for the LI-7500 Open Path CO2/H2O Analyzer. | install guide |
| Solution for Minimizing Surface Heating Effects for Open Path CO2 Flux Measurements in Cold Environments | Poster describing how to minimize potential effects of surface heating in open path CO2/H2O analyzers. | poster |
| Additional Heat Flux Term in the WPL Correction for the Open-path Gas Analyzer | Poster describing an additional term in the WPL corrections that can correct for instrument-related heat dissipation. | poster |
| Effects of temperature and pressure on CO2 infrared absorption with special emphasis on problems resulting from operation at high flow rates. | Article describing the effects of temperature and pressure on absorption of infrared energy by carbon dioxide. | publication |
| Effects of Temperature, Pressure, and Water Vapor on Gas Phase Infrared Absorbtion by CO2 | Article that describes the effects of temperature, pressure, and water vapor on absorption of infrared energy by carbon dioxide. | publication |
| Using the Sable Systems DG-4 to set the H2O span for LI-COR gas analyzers | You can adjust the H2O span in many LI-COR gas analyzers with a dewpoint generated by the Sable Systems DG-4 Dewpoint Generator. This tech tip provides some details. | tech tip |
| LI-7500 CO2/H2O Analyzer Communication Issues | Technical Note/FAQ about communication with the LI-7500. | tech tip |
| LI-7500A CO2/H2O Analyzer's Red LED Power Light Stays On | Technical Note/FAQ about problem with red LED power light not turning off on the LI-7500. | tech tip |
To request factory service or recalibration for an instrument:
Service will be performed at our US office in Lincoln, NE USA, European office (LI-COR GmbH), or by your local distributor.
