Search or filter tech tips on title keywords or instrument.

Summary
Re-seating the SD card in the LI-1500 and LAI-2200C Video showing how to reinstall the SD card in the LI-1500 and LAI-2200C. LI-1500, LAI-2200C
Communication with an LI-62x2 Analyzer Instructions for communicating with the LI-62xx gas analyzers. LI-6251, LI-6252, LI-6262
Where's My Serial Port? This note describes how to use a serial-to-USB adapter with instruments that required a RS-232 port. LI-6400/XT, LI-7500A/RS, LI-7200/RS, LI-7700, LI-8100/A
Ten Facts About the LI-6020 Battery Charger Information about the four-port battery charger. LI-6400/XT, LI-8100/A
Making an Instrument Toolkit A toolkit will help you be prepared for nearly any situation. LI-6400/XT, LI-6800
Using CO2 and H2O Scrubbers with LI-COR Gas Analyzers This note describes the internal chemical scrubbers that keep absorbing gases out of internal spaces in the optical bench. LI-6400/XT, LI-6800, LI-7500DS, LI-7500A/RS, LI-7200/RS, LI-7700
Shipping lithium-ion batteries Suggestions for storing and shipping lithium-ion batteries used with many LI-COR products. LI-6800, LI-7810, LI-7815, LI-7820, LI-7825, Smart Chamber
Testing instrument cables Video showing how to test a cable using a multi-meter. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8100/A, LI-8250
Troubleshooting Ethernet Connectivity Issues with LI-COR Gas Analyzers Suggestions for solving network issues. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
An Often-Overlooked Constraint to Powering Instruments: Voltage Drop Long cables can cause a voltage drop. This tip describes the problem and offers some solutions. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8100/A, LI-8250
Using a Cradlepoint Modem with LI-COR Eddy Covariance Systems Guidance for using a Cradlepoint Modem with remote eddy covariance systems. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
Troubleshooting Ethernet Connectivity Issues with LI-COR Gas Analyzers This document provides tips for connecting with network-enabled devices. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700
Dealing with Daylight Saving Time This technical tip advises against the use of daylight saving time when setting instrument clocks LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-8250, LI-8100A, Smart Chamber, LI-7700, LI-7810, LI-7815, LI-7825
Uploading data files to Dropbox Instructions for configuring Dropbox® and LI-COR eddy covariance systems (win-GHG software) or the LI-8250 Multiplexer to automatically transfer data on schedule. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
Air Pumps and Accessories for LI-COR Gas Analyzers Suggested parts and vendors for air pumps and other accessories needed to flush the sample cells of many LI-COR closed-path gas analyzers. LI-820, LI-840A, LI-830, LI-850, LI-7000
Temporary Fix for a Bad IR Source These tips might allow you to get a bit more data from an analyzer. LI-820, LI-840/A, LI-830, LI-870, LI-8100/A
Replacing the Source and Detector in the LI-8x0 Analyzers and LI-8100/A Instructions for replacing the optical source and detectors. LI-820, LI-840/A, LI-830, LI-850, LI-870, LI-8100/A