Introducing the
LI-7835 H2/CH4/H2O
Trace Gas Analyzer
LI-7835 H2/CH4/H2O
Trace Gas Analyzer
For your hydrogen prospecting or leak detection needs
Learn MorePRECISION, STABILITY, AND PORTABILITY
To monitor global emissions, you need a gas analyzer that meets rigorous requirements for accuracy, precision, and stability.
LI-COR Trace Gas Analyzers add new dimensions to your trace gas research and monitoring. They provide the same exceptional performance in the lab, in the field, or on the move for CO2, CH4, N2O, CO2 isotopologues, NH3, and H2 measurements.
Precise, stable, and portable with low power and low maintenance requirements, LI-COR Trace Gas Analyzers are reliable and rugged enough for the most extreme and remote locations, even at high altitudes—all at the precision and stability your work needs.
Go wherever your research takes you.
EXPLORE SOLUTIONSWebinar
Inside the Deep Soil Ecotron: New Opportunities for Deep Soil Research
November 11th (11 AM CT)
Learn MoreMETHOD MATTERS
For 35 years, LI-COR infrared gas analyzers have been used and trusted by researchers and networks around the world.
LI-COR laser absorption spectroscopy-based Trace Gas Analyzers are accompanied by a suite of patented technologies that contribute to their robust design and exceptional performance in CO2, CH4, N2O, CO2 isotopologues, NH3, and H2 measurements, allowing you to be flexible with your research site location.

* Wi-Fi connectivity limited in some countries
HIGH PERFORMANCE
The LI-7800 Trace Gas Analyzers use LI-COR's own Optical Feedback-Cavity Enhanced Absorption Spectroscopy (OF-CEAS) complemented by several patented technologies and innovations. The high-finesse optical cavity allows the laser to be reflected through the cavity multiple times, enhancing the signal severalfold.
A dense grid created by the fixed cavity resonance modes, in combination with tightly controlled cavity temperature and pressure, results in high resolution sampling with very low uncertainty. The combination of technology and sophisticated signal processing enables very fast and sensitive measurements with the long-term stability expected from laser absorption spectroscopy-based systems.

PATENTED DESIGN
LI-COR Trace Gas Analyzers incorporate multiple patented technologies. Our unique approach to the OF-CEAS method provides precision, portability, and stability to your measurements.
The result is a cost-effective analyzer that consistently delivers high performance and requires minimal maintenance anywhere and everywhere it goes. A highly stable optical bench requires less user calibration, allowing for long-term deployment. Combine the precision of a bench analyzer with the portability and flexibility needed for a wide range of research applications, including those performed at high altitudes.

GO WHEREVER YOUR RESEARCH TAKES YOU
Because LI-COR Trace Gas Analyzers were designed to be weather resistant and portable, you never sacrifice precision for location. The lightweight design and long-lasting, rechargeable batteries open new opportunities for remote research. An optional backpack harness makes reaching these locations easier.
CHOOSE YOUR APPLICATION, WITHOUT LIMITS
With options for high precision CO2, CH4, N2O, CO2 isotopologue, NH3, and H2 measurements. LI-COR Trace Gas Analyzers are designed to suit a range of research needs.
- Expand your monitoring capabilities across a city or other area of interest
- Explore renewable energy resources with in-situ prospecting
- Take mobile measurements for leak detection and site surveys
- Attach flasks for measuring CO2, CO2 isotopes, CH4, NH3, and N2O evolution of biological processes or animals
- Connect a 8200-01S Smart Chamber and LI-8250 Multiplexer System to measure ecosystem gas flux
For long-term measurements or remote locations, low power requirements mean you can operate the analyzers with solar or AC power. The durable, weather-resistant case requires no cooling apparatus, so there is no need for additional equipment or elaborate field structures. A simple cover or stand is all that is required.
Have the versatility to perform long-term or survey measurements for:
- Soil gas flux
- Urban emissions monitoring
- Mobile emissions monitoring
- pCO2 and pCH4
- Sensor networks
- Large area emissions monitoring
- Fugitive emissions
- Resource prospecting
- Incubation, respirometry, and flask sampling
- High altitude sites

TRACE GASES IN THE ECOSYSTEM
Whether you're measuring trace gases in the short term, long term, or on the move, integrating data from soil gas flux, plant physiology, and eddy covariance systems can help reveal the origin and destination of these gases and how they interact with other core processes in an ecosystem.
EXPLORE SOLUTIONSWEB-ENABLED FOR ON-THE-GO ACCESS
While the external, on-board display is great for a quick glance at concentration measurements and diagnostic alerts, diving into the details of your analyzer is effortless. Each instrument includes Wi-Fi* and a built-in web server with software designed for quick, easy access to the status of your instrument and current measurements.
Connect any device with a web browser and Wi-Fi—including your smartphone or tablet—to the intuitive interface. See live data and configure the instrument. If you cannot connect to Wi-Fi, connect the instrument directly to your computer or network using the Ethernet cable. Regardless of which device you connect with, you will have the full software in front of you.


TRACE GAS ANALYZER PRODUCTS
LI-COR laser absorption spectroscopy-based Trace Gas Analyzers use a suite of patented technologies to deliver high quality results in the field and on the go. Highly precise and stable, the analyzers are rugged and portable, so you can go wherever your research takes you.
LI-7810
CH4/CO2/H2O Trace Gas Analyzer
When methane is what you are most interested in, the LI-7810 delivers exceptionally stable and precise methane measurements with good carbon dioxide and water vapor measurements. The LI-7810 is also ideal for chamber-based soil flux measurements.
Learn moreRequest a QuoteLI-7815
CO2/H2O Trace Gas Analyzer
For applications that demand exceptionally sensitive and stable carbon dioxide measurements at sub-ppm precision, the LI-7815 is an ideal choice.
Learn moreRequest a QuoteLI-7820
N2O/H2O Trace Gas Analyzer
Providing precise N2O measurements for chamber-based soil gas flux research and more. Because of its compact, low power, and portable design, you can take the analyzer wherever you need to go and measure nitrous oxide for various applications.
Learn moreRequest a QuoteLI-7825
CO2 Isotope/NH3 Trace Gas Analyzer
Rugged and portable for the field, the LI-7825 measures the four most abundant CO2 isotopologues in air and reports δ13C, δ17O, and δ18O with high precision and accuracy.
Learn moreRequest a QuoteNEW! LI-7835
H2/CH4/H2O Trace Gas Analyzer
Takes precise trace concentration measurements of gaseous H2 and CH4 simultaneously. It provides direct and accurate measurements with a battery-powered, weather-resistant, and portable design.
Learn moreRequest a Quote