LI-COR Logo (White)LI-COR Logo

Trade in your LI-6400/XT for a new LI-6800

Request a Quote

Future-Proof Your Lab's Legacy

The LI-6400/XT Portable Photosynthesis System has been the backbone of countless discoveries in your lab, delivering results you can trust. And as research evolves, the tools you rely on must evolve, too. Upgrading to the LI-6800 equips your team with a tool that's not only as reliable (and durable) as the LI-6400/XT but more powerful, versatile, and easier for the next generation of researchers to use.

Don't let yesterday's technology hold back tomorrow's breakthroughs. Ensure your work continues to drive innovation by trading in your LI-6400/XT for the LI-6800 today.

What Your Colleagues Are Saying

Don't just take our word for it—see why other researchers have upgraded to the LI-6800 and how it continues to transform their work.

Switching from the LI-6400XT to the LI-6800 sig-nificantly upgraded our user experience—[the] new software functions and rapid A/Ci curves, USB data transfer, touchscreen, and intuitive interface have made it easier and more intuitive to collect measurements.

Dr. Katie M. Murphy
Director of Phenotyping and Principal Investigator,
Donald Danforth Plant Science Center

The Dynamic Assimilation Technique [only available on the LI-6800] is really helpful and will truly be a potential that hasn't been tapped into yet by the field.

Dr. Berkley Walker
Associate Professor,
Michigan State University
Plant Research Laboratory/Plant Biology

Why It's Better

6800 touch screen is easy to use

Easier to Use

Quickly navigate the LI-6800 with a large color display, touchscreen, and one-button start—the ideal design for new and seasoned researchers alike.

Learn More
battery icon

More Chamber Options

Go beyond terrestrial plant physiology with the Aquatic Chamber or dive deeper with additional chambers and accessories for needles, soil, and custom applications.

Learn More
files icon

Faster Results

Get full response curves in a fraction of the time using the Dynamic Assimilation Technique (DAT), available only on the LI-6800 with the 6800-01A Fluorometer.

Learn More
files icon

Same Trusted Quality

Continue relying on the global standard of plant research technology and the trusted support you expect from LI-COR photosynthesis systems.

Learn More

A Side-by-Side Comparison

Interested in the details? See how the specifications of both instruments stack up. Use the show/hide sections below to see how the LI-6800 offers real-world advantages for your lab.

LI-6400/XTLI-6800THE LI-6800 ADVANTAGE
Precision
CO2 Analyzer PrecisionWithin 0.2 μmol mol-1 RMS with 4-second averaging at 400 μmol mol-1Within 0.1 μmol mol-1 RMS with 4-second averaging at 400 μmol mol-1Contributes to better, faster, and more repeatable CO2 flux at higher flow rates
H2O Analyzer PrecisionWithin 0.017 mmol mol-1 RMS with 4-second averaging at 10 mmol mol-1Within 0.010 mmol mol-1 RMS with 4-second averaging at 10 mmol mol-1More accurate and repeatable data collection
H2O Control
Software Automated H2O ControlNo

Requires manual intervention (knob) and is dependent on flow rate
Yes

Fully automated under software control
Faster, more accurate, and more precise control at the desired setpoint

More repeatable H2O flux, conductance, and Ci data
H2O Control Independent of Flow ControlNoYesNew chemical column design makes it easier to service the chemicals
CO2 Control
CO2 Cartridges12g8gReadily available worldwide and less likely to be contaminated by oil. No filtering required
Lowest CO2 Control Point (other than zero) without system modificationAbout 50 ppmAbout 1 ppm
Lowest CO2 control point dependent upon no buffering of CO2 in humidification or desiccant source.
More precision and broader range of operation results in more accurate determination of CO2 compensation point
Flow, Leaks, and Matching
FlowSplit in consoleSplit in sensor headReduces potential for differential diffusion and sorption rates that can result in systematic biases
Maximum Flow750 µmol s-11400 µmol s-1Faster measurements and more latitude in larger chamber designs
Chamber OverpressureManualAutomatic/measured/ user controlledCreates small outward flow from chamber to counteract inward diffusion leaks
Range MatchingNo

Air goes from leaf chamber to reference analyzer
Yes

Reference air goes directly to both analyzers
Faster and more accurate range matching
Temperatures
Operating Temperature Range0 -50 °C0-50 °CWide operating range for both instruments
Leaf Temperature Control Range± 6 °C from ambient± 10 °C from ambientExpanded range of temperature control adds experimental flexibility to the instrument
Leaf Temperature SensorType E fine wire thermocoupleType E fine wire thermocouple (more robust design with capability to do 2X measurements)Maintains low thermal mass of fine wire while improving reliability of sensor
Tleaf Derived from Energy BudgetAvailableAvailableNon-contact determination of Tleaf from energy budget calculation due to accurate, more uniform characterization of light on leaf, and more precision on H2O measurement
Software
Dynamic Assimilation TechniqueNoYesSaves time, improves measurement quality, and allows for measurements under dynamic environmental conditions
Console DisplayBacklit 8x40 character LCD with character key controlLarge color touch screenInteractive and easy to view
Sensor Head DisplayNoneThree lines of variablesAbility to view data when console display is not in view
Illustrated Workflow of Environmental ControlsNoYesIntuitive and easy to learn for users of all experience levels
Customizable Background ProgramsNoYesCustomize CO2 and light response curves or create a unique sampling protocol to standardize experiments and data collection
System AlertsA fewManyMore warnings and alerts help guide users to optimal performance and data collection
System TestsLimitedAutomatedEasy to check instrument functionality
Power
Ah Per Battery
(When New)
3.4
(3.4 X 2 = 6.8 Ah per charge)
6.8
(6.8 X 2 = 13.6 Ah per charge)
Battery Power Density2.1 Ah/kg15.1 Ah/kgProvides more power in a smaller battery
Weight/Ergonomics
Total System Weight, Fully Configured12.69 kg9.98 kgEasier to carry
Wheeled Carrying CaseNoYesRoll, rather than carry, instrument case
Dedicated Accessories CaseNoYesErgonomic foam inserts for organization of accessories
Tripod for ConsoleNo

Sensor head mount only
YesCan be used to support either the sensor head or console
Carrying HarnessNoYesCan be used to support either the sensor head or console
Fluorometer
Leaf Aperture2 cm22 cm2 or 6 cm2A larger chamber aperture allows for more uniform light distribution, which improves fluorescence and gas exchange measurement accuracy
Fluorometer Saturating Flash7,000 µmol m-2s-116,000 µmol m-2s-1Capable of significantly higher flash intensities, which allows for more accurate estimation of maximum fluorescence and derived parameters
Multiphase™ Flash Fluorescence CapableYesYesMultiphase Flash fluorescence protocol estimates maximum light-adapted chlorophyll fluorescence (Fm') at lower flash intensities, reducing potentially negative flash-induced effects
Induction KineticsNoYesHigh-frequency modulation provides high-resolution transient measurements for induction kinetics
Modulation FrequencyFour Presets

0.25, 1, 10, and 20 kHz
Fully customizable dark and light modulation frequencies

10 Hz to 50 kHz
Greater flexibility to suit a variety of research applications and sample materials
DC PSII FluorescenceNoYesTakes continuous measurements of chlorophyll fluorescence
Data and Communications
Console Memory128 mb operation and 64 mb data storage2 GB operation and 8 GB flash data storageSignificantly more memory for faster operation and storage of data
EthernetYesYes
Miscellaneous
Chamber Latching MechanismManually adjusted pressureConstant pressureMore uniform, consistent pressure on leaf
Improved Chemical ColumnsNoYesEasier to fill, seal, and attach to the console, requiring minimal maintenance.
Console MaintenanceMany internal replaceable fuses and a filterInternal resettable fuses and one console filterReduced maintenance requirements

Leaf Chamber(s)

LI-6800 chambers and light sources accommodate leaves of nearly any shape and size, algae, and other aquatic organisms. See which ones are ideal for your environmental work.