Application Notes, Tech Tips, and Other Documents

Summary
Calibration Procedures for LI-COR Spectroradiometers, Radiation Sensors, and Lamps This application note summarizes LI-COR factory calibration procedures for all quantum sensors, photometric sensors, and spectroradiometers. application note
Principles of Radiation Measurement

Brochure describing the fundamental principles of light and radiation measurements using light sensors.

brochure
Using the 2420 with quantum sensors Installation instructions for the 2420 light sensor amplifier and the LI-190 and LI-190R quantum sensors. install guide
Using the 2420-BLS Light Sensor Amplifier with long-term soil CO2 flux chambers and the LI-8150 multiplexer Installation guide for light sensors using the 2420 amplifier with the LI-8100A system. install guide
LI-190R and LI-191R Quantum Sensors Instruction Manual Instruction manual for the LI-190R Quantum Sensor and LI-191R Line Quantum Sensor. manual
LI-COR Terrestrial Radiation Sensors Instruction Manual Instruction manual for older LI-COR light sensors, including the LI-190, LI-191, LI-200, and LI-210. manual
The Importance of Light Measurements in the Cultivation of Cannabis Poster that describes considerations for the lighting environment when cultivating cannabis. poster
Using LI-COR light sensors with National Instruments wireless sensor networks Technical note describing how to use LI-COR light sensors in National Instruments Wireless Sensor Networks technical note
A Comparison of Quantum Sensors with Different Spectral Sensitivities Technical note describing the spectral sensitivity of different types of quantum sensors. technical note
Creating a wireless light sensor network with Particle Argon platform Describes how to create a Wi-Fi sensor network that automatically posts results to a Google Note using off-the-shelf components. tech tip
Using LI-COR light sensors with National Instruments wireless sensor networks Technical note describing how to use LI-COR light sensors in National Instruments Wireless Sensor Networks tech tip
Preventing Negative Readings with LI-COR Light Sensors Tech tip that describes why you might get negative readings from a LI-COR light sensor and how to solve the problem. tech tip
Connecting LI-COR light sensors to voltage-reading data loggers Tech tip that describes how to connect a light sensor to a voltage reader or datalogger. tech tip
Amplifying the Output Signal from LI-COR Radiation Sensors Technical tip describing how to amplify the signal from LI-COR radiation sensors for use with other manufacturer's data logging devices. tech tip
Calculation of Multiplier from Campbell Scientific Purchased Sensors (LI-190) This technical tip describes how to calculate the multiplier for a LI-COR LI-190 Quantum Sensor that has been modified and purchased from Campbell Scientific. tech tip