Application Notes, Tech Tips, and Other Documents

Summary
Calibration Procedures for LI-COR Spectroradiometers, Radiation Sensors, and Lamps This application note summarizes LI-COR factory calibration procedures for all quantum sensors, photometric sensors, and spectroradiometers. application note

Immersion Effects and Cosine Collecting Properties of LI-COR Underwater Radiation Sensors

Application note describing how to correct for immersion effects in order to obtain absolute values of irradiance under water.

application note
Principles of Radiation Measurement

Brochure describing the fundamental principles of light and radiation measurements using light sensors.

brochure
Using the 2420 with pyranometers Installation instructions for the 2420 light sensor amplifier and the LI-200 and LI-200R pyranometers. install guide
Using the 2420-BLS Light Sensor Amplifier with long-term soil CO2 flux chambers and the LI-8150 multiplexer Installation guide for light sensors using the 2420 amplifier with the LI-8100A system. install guide
LI-200R Pyranometer Instruction Manual Instruction Manual for the LI-200R Pyranometer. manual
LI-COR Terrestrial Radiation Sensors Instruction Manual Instruction manual for LI-COR light sensors, including the LI-190, LI-191, LI-200, and LI-210. manual
Using LI-COR light sensors with National Instruments wireless sensor networks Technical note describing how to use LI-COR light sensors in National Instruments Wireless Sensor Networks technical note
A Comparison of Quantum Sensors with Different Spectral Sensitivities Technical note describing the spectral sensitivity of different types of quantum sensors. technical note
Using LI-COR light sensors with National Instruments wireless sensor networks Technical note describing how to use LI-COR light sensors in National Instruments Wireless Sensor Networks tech tip
Creating a wireless light sensor network with Particle Argon platform Describes how to create a Wi-Fi sensor network that automatically posts results to a Google Note using off-the-shelf components. tech tip
Preventing Negative Readings with LI-COR Light Sensors Tech tip that describes why you might get negative readings from a LI-COR light sensor and how to solve the problem. tech tip
Connecting LI-COR light sensors to voltage-reading data loggers Tech tip that describes how to connect a light sensor to a voltage reader or datalogger. tech tip
Amplifying the Output Signal from LI-COR Radiation Sensors Technical tip describing how to amplify the signal from LI-COR radiation sensors for use with other manufacturer's data logging devices. tech tip
LI-200 Pyranometer Sensor Calculation of Multiplier from Campbell Scientific Purchased Sensors This technical tip describes how to calculate the multiplier for a LI-200 or LI-200R Pyranometer that has been modified and purchased from Campbell Scientific. tech tip