Instruction Manuals
Original SmartFlux System Instruction Manual
(EC_Manual_SMARTFlux_System_13838.pdf)
Instruction manual for the original SmartFlux system that installs inside the LI-7550.
Analog Sonic Anemometer Cables Installation Guide
(EC_InstallGuide_Sonic_Data_Cables_11442)
Installation instructions for connecting analog anemometers to the LI-7550, for use with the LI-7500A/RS or LI-7200/RS.
Software and Firmware
Here you'll find SmartFlux System (original) embedded software and compatible software for other components of the eddy covariance system. The following table lists the current software versions for LI-COR Eddy Covariance software components. Note that some instruments require updates to both interface and instrument (embedded) software. Note, too, that factory releases of compatible interface and embedded software do not always occur in tandem, so version numbers may not be in sync.
| EddyPro Software |
win-GHG (LI-7200/RS) |
win-GHG (LI-7500A/RS) |
win-GHG (LI-7500DS) |
Original SmartFlux |
LI-7700 | Biomet System (Sutron) |
|
|---|---|---|---|---|---|---|---|
| Interface Software: | Windows v7.0.9 macOS v7.0.9 |
Windows v8.9.2 | Windows v8.9.2 | Windows v8.9.2 | na | Windows v1.0.9 | See Sutron Support |
| Embedded Firmware: | na | Windows v8.9.0 | Windows v8.9.0 | Windows v1.0.9 macOS v1.0.9 |
Windows v1.5.3 | Windows v1.0.29 | Biomet Programs v5 |
| Changes | Changes / Instructions | Changes / Instructions | Changes / Instructions | Changes / Instructions | Changes / Instructions | Changes |
(smartflux-updater-1.5.3.zip)
Original SmartFlux System software package. Unpack the archive and double-click the flux updater.exe file. Select the SmartFlux that system you want to update and click Update Firmware.
Videos
Frequently Asked Questions
Original SMARTFlux System:
- For use with the LI-7500A/RS or LI-7200/RS.
- Installs inside the LI-7550.
- Reads analog data from the sonic anemometer.
- The original SMARTFlux operating instructions are available here.
SmartFlux 2 System:
- For use with the LI-7500A/RS or LI-7200/RS
- Installs inside an enclosure. GPS antenna installs outside the enclosure.
- Reads digital data and diagnostics from the sonic anemometer.
- The SmartFlux 2 System operating instructions are in the LI-7500A/RS instruction manual and LI-72000/RS instruction manual.
SmartFlux 3 System:
- For use with the LI-7500DS.
- Installs inside an enclosure. GPS antenna installs outside the enclosure.
- Reads digital data and diagnostics from the sonic anemometer.
- The SmartFlux 3 System operating instructions are included with the LI-7500DS Instruction Manual.