Odyssey® M
Imaging System

A fusion of the industry’s most sophisticated imager with innovative software to power you toward scientific discovery.

Get a Quote
Odyssey M
plate, membrane, gel, slides

Go where your experiments lead you

Expand your research opportunities and prepare your lab for the future with consistent and reliable imaging of dozens of assays spanning up to 18 channels.

3-color Western Blot, imaged on Odyssey M, tmu-748-99-1

Quantitative Western Blots

Chemi Western blot, imaged on Odyssey M, sd774-157-1

Qualitative Western Blots

Protein gel, imaged on Odyssey M, ds840-27.jpg

Protein Gels

GFP, imaged on Odyssey M, mab-559-110-1

GFP Assays

In-Cell Western blot,, imaged on Odyssey M, mab-848-095-1
In-Cell Western blot, imaged on Odyssey M, skm-842-34-01

In-Cell Western Assay

Nucleic Acid Gel, imaged on Odyssey M, ds840-24-1

Nucleic Acid Gels

Tissue section, imaged on Odyssey M

Tissue Section Imaging

One instrument provides you and your lab with access to a wide range of assays, including membranes, plate-based assays, slides, and gels. With the Odyssey M Imager, you have the flexibility to adapt to a variety of research options and to follow-up on leads with additional experimentation.

Experiment with multiple targets in multiple channels

Get more data out of each assay with the versatility to acquire images in up to 18 channels with dozens of combinations, including 3-color Western blots and In-Cell Western™ Assays.

Multiplex detection and channel overlays allow you to compare different targets captured at the same time, under the same conditions, to improve consistency.

Capture data from dozens of assays in near-infrared and visible fluorescent, colorimetric, bioluminescent, and chemiluminescent wavelengths.

Odyssey M Imager Channel Options*

Channel Excitation Emission Dye/Stain Examples
800 785nm 816-840nm IRDye® 800CW
700 685nm 721-745nm Revert™ 700 Total Protein Stain, CellTag™ 700 Stain, IRDye 680RD, Alexa Fluor® 680, DRAQ5® stain
520 520nm 570-610nm Revert 520 Total Protein Stain, CellTag 520 Stain, VRDye™ 549, Cy3, Alexa Fluor 546, Red Fluorescent Protein (RFP)
520A 520nm 721-740nm DRAQ5
520B 520nm 816-840nm Custom
488 488nm 519-543nm VRDye 490, FITC, Green Fluorescent Protein (GFP)
488A 488nm 570-610nm SPYRO® Ruby
488B 488nm 721-740nm StarBright Blue 700
488C 488nm 816-840nm Custom
Chemi N/A N/A HRP/AP Substrates, Bioluminescence
RGB Epi 470, 525, 630 Epi N/A Custom
630 Epi 631-659nm Clear Window Pierce™ Reversible Protein Stain, TMB (blotting)
525 Epi 500-530nm Clear Window Ponceau S, NBT/BCIP
470 Epi 447-472nm Clear Window Custom
RGB Trans 470, 535, 630 Trans N/A H&E Stain
630 Trans 631-659nm Clear Window Coomassie Blue Stain, TMB - non stopped (ELISA)
525 Trans 500-530nm Clear Window OPD (ELISA)
470 Trans 447-472 Trans Clear Window Silver Stain, TMB - stopped (ELISA)
IRDye, VRDye, Revert, and CellTag are trademarks or registered trademarks of LI‑COR, Inc. in the United States and in other countries. Third party trademarks, trade names, and product names may be trademarks or registered trademarks and are the property of their respective owners.
LI-COR Odyssey M open with Multiwell Plate overhead

Be confident in your data

The Odyssey M Imager employs the industry’s most sophisticated technology to produce exceptional quality data for a wide range of assays.

The line-scanning system of the Odyssey M combines high-output laser excitation with sCMOS sensor technology to capture the full range of your data in a single acquisition with exceptional quality and consistency to keep your research moving forward.

The Odyssey M delivers

  • Uniform illumination across the entire scanning area for all channels
  • Optimal sensitivity to reveal subtle changes between samples
  • Over 6 logs of dynamic range to eliminate imager saturation in biologically relevant samples
  • Industry-leading 5-micron resolution to see exceptional detail

Exclusive acquisition and analysis software

The Odyssey M Imaging System pairs your Odyssey M Imager with LI-COR Acquisition Software and Empiria Studio® Software to maximize data quality, consistency, and replicability using best practices provided by industry experts.

data illustration
LI-COR Acquisition Software

LI-COR Acquisition Software

LI-COR Acquisition Software is used to acquire, organize, and adjust images from your Odyssey M Imager. Workflows guide you through the necessary steps using identical settings based on assay type to minimize sources of variability. Images are organized by assay and can be adjusted then exported for publication or analysis in Empiria Studio Software.

Empiria Studio

Empiria Studio Software

Designed for the analysis of a variety of assay images acquired on an Odyssey imager, Empiria Studio is the only software developed using best practices to guide you all the way from validation to statistical analysis for reliable results. Streamlined workflows minimize user-to-user variation, compute statistical values, and provide extensive analysis options.

Learn More about Empiria Studio

western blot consistent results skm-842-138-02

Get consistent, reliable results— every time

Each component of the Odyssey M Imaging System has been carefully considered to inherently minimize variability.

All images are captured using the same optical settings and, where possible, in a single acquisition. Users don’t need to adjust exposure time or laser intensity to obtain non-saturated images and available alignment guides ensure that plates and slides are positioned consistently.

Guided workflows in LI-COR Acquisition and Empiria Studio Software and features, such as Adaptive Lane Finding and Adaptive Background Subtraction, further eliminate sources of variability.

Odyssey M Western Blot Image Sequence  skm-842-138-02 3 Odyssey M Western Blot Image Sequence  skm-842-138-02 4 Odyssey M Western Blot Image Sequence  skm-842-138-02 5 Odyssey M Western Blot Image Sequence  skm-842-138-02 6 Odyssey M Western Blot Image Sequence  skm-842-138-02 7 Odyssey M Western Blot Image Sequence  skm-842-138-02 8 Odyssey M Western Blot Image Sequence  skm-842-138-02 9 Odyssey M Western Blot Image Sequence  skm-842-138-02 10 Odyssey M Western Blot Image Sequence  skm-842-138-02 11 Odyssey M Western Blot Image Sequence  skm-842-138-02 12 Odyssey M Western Blot Image Sequence  skm-842-138-02 13 Odyssey M Western Blot Image Sequence  skm-842-138-02 14 Odyssey M Western Blot Image Sequence  skm-842-138-02 15 Odyssey M Western Blot Image Sequence  skm-842-138-02 16 Odyssey M Western Blot Image Sequence  skm-842-138-02 17 Odyssey M Western Blot Image Sequence  skm-842-138-02 18 Odyssey M Western Blot Image Sequence  skm-842-138-02 19 Odyssey M Western Blot Image Sequence  skm-842-138-02 20 Odyssey M Western Blot Image Sequence  skm-842-138-02 21

Answer your research questions quickly

From acquisition to analysis, the Odyssey M Imaging System enables you to quickly obtain reliable results you can use to answer your research questions—or ask new ones.

in-cell western, linear range, scatter plot
 

The Odyssey M Imager lets you power through your image acquisitions with fast scanning and a large scan area to image multiple blots, slides, plates, and gels at once. User-definable scan areas in LI-COR Acquisition Software ensure you only scan the regions you’re interested in.

With Empiria Studio Software, project-based organization keeps related data at hand and statistical analysis tools handle the complex math to yield in-depth statistical analysis in minutes–not hours.

Odyssey M

See the Odyssey M in action

Power your research forward with the consistent, high-quality imaging technology that has propelled Odyssey imagers to over 25,000 peer-reviewed publications. See the benefits of 18 imaging channels and multiple target detection. The industry’s most sophisticated imager delivers the most accurate results and industry-leading 5-micron resolution. Make discoveries and decisions quickly with high confidence.

Need more information? Contact us.

* Remote demonstrations are available.

chat icon disabledLooking to chat with support? First, you will need to accept cookies.
Open Cookie Preferences
chat iconChat With Us
chat icon disabled