Sierra Wireless has confirmed reports of ‘Mirai’ malware infecting the AirLink® RV-50 and LS300 wireless gateways. If your gateway uses the default ACEmanager password and is reachable from the public internet, the malware can use the firmware update function to download and copy a version to the memory. The malware proceeds to scan for vulnerable devices, reports findings to a control server, and participates in a Distributed Denial of Service (DDoS) attack. The best indicator of the malware is abnormal traffic on TCP ports 23 and 48101. Additional details are available on the following Sierra Wireless technical bulletin: source.sierrawireless.com/resources/airlink/software_reference_docs/technical-bulletin/sierra-wireless-technical-bulletin---mirai/. As stated in the bulletin, the recommended course of action to remove the malware is to reboot the gateway, change the default ACEmanager password to a secure password. We also recommend that you run the latest version of ALEOS software on the device (source.sierrawireless.com/resources/airlink/software_downloads/rv50/rv50-firmware-list/).

Manuals

Using the RV-50X with LI-COR Eddy Covariance and Soil Gas Flux Systems Instruction Manual

(EC_Manual_RV50X_Cellular_17122 Rev3)

Instruction manual for cellular communication systems with the Sierra Wireless RV-50X wireless gateway. This edition describes biomet systems that include the LI-COR Data Acquisition System (manufactured after June 17, 2019).

Sierra Wireless RV50 Cellular Communication Instruction Manual

(EC_Manual_RV50_Cellular_17122.pdf)

Instruction manual for cellular communication systems with the Sierra Wireless RV-50 wireless gateway. This edition describes biomet systems that include the Sutron logger (manufactured before June 17, 2019).

Sierra Wireless LS300 Cellular Communication Instruction Manual

(EC_Manual_LS300_Cellular_13835.pdf)

Instruction manual for cellular communication systems with the Sierra Wireless LS300 AirLink wireless gateway.

FAQs

All Documents

Summary
DIY Cellular Communication for EC Systems This document describes what you need to connect your LI-COR EC system to the internet using a Cellular Gateway install guide
Sierra Wireless RV50X Cellular Communication Instruction Manual Describes how to deploy the RV50X in eddy covariance and soil gas flux systems that have a LI-COR Data Acquisition System. manual
Sierra Wireless RV50 Cellular Communication Instruction Manual Describes how to deploy the RV50 in eddy covariance and soil gas flux systems that have a Sutron logger. manual
Sierra Wireless LS300 Cellular Communication Instruction Manual Describes how to deploy the LS300 in eddy covariance and soil gas flux systems. manual