Application Notes, Tech Tips, and Other Documents

Summary
NEW! Logging sun-induced fluorescence, reflectance, and vegetation indices in EC datasets Instructions for using the JB Hyperspectral Devices RoX and FloX instruments with LI-COR eddy covariance systems. This enables you to log sun-induced fluorescence and reflectance parameters, as well as vegetation indices, in eddy covariance data sets. application note
NR Lite2 Net Radiometer Installation Guide Instructions for using the NR Lite 2 in biomet sensor packages install guide
NR01 Net Radiometer Installation Guide Instructions for using the Hukseflux NR01 net radiometer in biomet systems. install guide
CNR4 4-component Radiometer Installation Guide Instructions or using the CNR4 in biomet packages. install guide
CNF4 Heater and Ventilation Unit for the CNR4 Installation guide for the Kipp & Zonen CNF4 heater and ventilation unit accessory for the CNR4 install guide
LI-190R Quantum Sensor Installation Guide Instructions for using the LI-190R in biomet sensor packages install guide
LI-200R Pyranometer Installation Guide Instructions for using the LI-200R Pyranometer in biomet sensor packages. install guide
HMP-155 Humidity and Temperature Probe Installation Guide Instructions for using the HMP155 in biomet sensor packages install guide
7900-180 LI-COR Soil Temperature Sensor Installation Guide Instructions for using the 7900-180 soil temperature probe in biomet sensor packages. install guide
EC-5 Soil Moisture Probe Installation Guide Instructions for using the EC-5 in the Basic biomet sensor package install guide
Stevens HydraProbe Installation Guide Instructions for using the Stevens HydraProbe (SDI-12) in biomet sensor packages install guide
HFP01 Soil Heat Flux Plates Installation Guide Instructions for using Soil Heat Flux Plates in biomet sensor packages install guide
HFP01SC Self-calibrating Soil Heat Flux Plates Installation Guide Instructions for using Self-calibrating Soil Heat flux Plates in biomet sensor packages. install guide
TR-525M Rain Gauge Installation Guide Instructions for using the Texas Electronics TR-525M rain gauge in biomet sensor packages. install guide

Using Campbell Scientific Dataloggers to Collect Biomet Data

Document describing how to use the CR3000, CR1000, or CR6 to record biological and meteorological data in a LI-COR eddy covariance system.

install guide
AirLink RV-50/X Cellular Communication Manual (with LI-COR Data Acquisition System) Instruction manual for cellular communication systems with the Sierra Wireless AirLink RV-50 wireless gateway in biomet systems that include the LI-COR Data Acquisition System. manual
AirLink LS300 Cellular Communication Manual Instruction manual for cellular communication systems with the Sierra Wireless AirLink LS300 wireless gateway. manual
Heavy Duty Adjustable Tripod Instruction Manual

Instruction manual for the Heavy Duty Adjustable Tripod.

manual
Satellite Communication for Eddy Covariance and Soil Gas Flux Systems Instruction manual for satellite communication systems. manual
SmartFlux 2 System Instruction Manual Instruction manual for the SmartFlux 2 System. manual
SunWize Solar Power Supplies Instruction Manual Instruction manual for using SunWize solar power supplies with LI-COR equipment. manual
New tools for a comprehensive time- and space-synchronized flux, weather, and soil optical sensor networks Poster presentation from the European Geophysical Union (2018) meeting that describes the integration of measurements across scales. poster
Data Acquisition Module Quick-start Guide Quick-start guide with basic information about the Data Acquisition Module quick-start guide
Data Retention Module Quick-start Guide Quick-start guide with basic information about the Data Retention Module quick-start guide
Using a Cradlepoint Modem with LI-COR Eddy Covariance Systems This technical tip describes how to use a Cradlepoint modem to enable remote communications with LI-COR eddy covariance systems. tech tip
Solar power supply considerations Describes how to determine the correct size of solar and battery power supply for an eddy covariance site. tech tip