IRDye® 800CW Donkey anti-Mouse IgG Secondary Antibody

IRDye 800CW Donkey anti-Mouse IgG Secondary Antibody

Immunogen

Mouse IgG

Purity and Specificity

The antibody was isolated by affinity chromatography using antigens coupled to agarose beads. Based on ELISA, this antibody reacts with the heavy and light chains of mouse IgG, and with the light chains of mouse IgM and IgA. This antibody was tested by ELISA and/or solid-phase adsorbed to ensure minimal cross-reactivity with bovine, chicken, goat, guinea pig, horse, human, rabbit, and sheep serum proteins, but may cross-react with immunoglobulins from other species. The conjugate has been specifically tested and qualified for Western blot and In-Cell Western assay applications.

Applications

Highly Recommended for:

  • Western Blot
  • In-Cell Western Assay
  • On-Cell Western Assay
  • Protein Array
  • Immunohistochemistry
  • Small Animal Imaging
  • Microscopy
  • 2D Gel Detection
  • Tissue Section Imaging
  • Virus Titration Assay

Formulation

IRDye 680LT secondary antibodies are supplied as purified immunoglobulin conjugates, lyophilized in phosphate-buffered saline, pH 7.4. Protect from light. Store at 4 °C prior to reconstitution.

Each vial contains 10 mg/mL BSA (free of IgG and protease) as a stabilizer and 0.01% sodium azide as a preservative, after reconstitution. Concentration is 1.0 mg/mL when reconstituted as directed. Refer to the pack insert for details on reconstitution.

Recommended Dilutions

Application Recommended Suggested Range
Odyssey Western blot detection 1:15,000 1:5,000 - 1:25,000
In-Cell Western assay detection 1:800 1:200 - 1:800
Other User optimized

Optimum dilutions will vary and should be determined empirically.

RRID

  • P/N 925-32212: RRID AB_2716622
  • P/N 926-32212: RRID AB_621847

Example Data

IRDye 800CW Donkey anti-Mouse IgG Secondary Antibody Data
Western blot analysis of PTEN expression in mouse PTEN transfected 293T whole cell lysate (lane 2) and non-transfected 293T lysate (lane 3). Both lysates were loaded with 2 µg total protein per lane. Odyssey® One-Color Molecular Weight Marker (P/N 928-40000) was loaded in lane 1. The blot was probed with mouse ant-PTEN (IgG2b) (Santa Cruz sc-133197) and chicken anti-GAPDH (ProSci XW-7214) followed by detection with IRDye 800CW Donkey anti-Mouse (P/N 926-32212) and IRDye 680LT Donkey anti-Chicken (P/N 926-68028).

Selected P/N: 926-32212,925-32212

Price

Quantity

Add to Cart

+ Add to WishlistAdded. Go to Wishlist

Resources

chat iconChat With Us
chat icon disabled