VRDye 490 Streptavidin

VRDye 490 Streptavidin

VRDye 490 Streptavidin

VRDye 490 Streptavidin is supplied as a liquid in buffer containing 10 mM phosphate, 183 mM NaCl, 2.7 mM KCl, pH 7.4 with sodium azide 0.005% (w/v) as a preservative.

To use, centrifuge briefly before use to eliminate aggregates that may have formed in solution. This will reduce non-specific background staining.

For membrane-based applications and In-Gel Westerns, it is recommended to add SDS (0.02% to 0.1% final concentration), in addition to Tween® 20 (0.1 to 0.2% final concentration) during the detection incubation step to reduce non-specific background staining.

Recommended Dilutions

Application Suggested Range Tween 20* SDS*
Western blot detection 1:2,000 - 1:5,000 0.1 - 0.2% (v/v) 0.02 - 0.1% (v/v)
Other User optimized User optimized User optimized

Optimum dilutions will vary and should be determined empirically.

* Added to reduce non-specific background staining.

Selected P/N: 926-49030

Price

Quantity

Add to Cart

+ Add to WishlistAdded. Go to Wishlist

Generate an Autoquote

Resources

chat icon disabledLooking to chat with support? First, you will need to accept cookies.
Open Cookie Preferences
chat iconChat With Us
chat icon disabled